Hanson Square: Difference between revisions

From FireAlarmPedia
No edit summary
(Confirmed panel model and location and added ISOs and relays.)
Line 5: Line 5:
|  
|  
|-
|-
| FACP: Notifier NFS2-640C <br /> FACP Location: Unknown <br />System Type: Addressable <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br /> System Coding: Temporal <br> Strobes Synchronized: Yes, SS <br />Date of last known Upgrade: N/A <br />Year Opened: 2012
| FACP: Notifier NFS-320C <br /> FACP Location: Office Main Entrance<br />System Type: Addressable <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br /> System Coding: Temporal <br> Strobes Synchronized: Yes, SS <br />Date of last known Upgrade: N/A <br />Year Opened: 2012
|}
|}


Line 12: Line 12:
==System Specifications==
==System Specifications==
====FACP====
====FACP====
The building is protected by a Notifier NFS2-640C addressable fire alarm system.  The panel location is unknown.  The system runs Notifier’s FlashScan addressable protocol, and the system coding is temporal.
The building is protected by a Notifier NFS-320C addressable fire alarm system.  The panel is located in the office main entrance vestibule.  The system runs Notifier’s FlashScan addressable protocol, and the system coding is temporal.


=====Annunciators=====
=====Annunciators=====
Line 28: Line 28:


====Modules====
====Modules====
There are Notifier FMM-1A addressable monitor modules supervising the sprinkler system’s tamper and flow switches.
There are Notifier FMM-1A addressable monitor modules supervising the sprinkler system’s tamper and flow switches.  There are Notifier FRM-1A addressable relay modules for elevator recall.  There are Notifier ISO-XA isolator modules on the SLC.
[[]
[[]

Revision as of 11:09, 29 December 2023

System Specifications
FACP: Notifier NFS-320C
FACP Location: Office Main Entrance
System Type: Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VDC
System Coding: Temporal
Strobes Synchronized: Yes, SS
Date of last known Upgrade: N/A
Year Opened: 2012

Hanson Square is a mixed-use retail/office building located at 909 17 Avenue Southwest, in Downtown Calgary, Alberta, Canada. The building houses Best Buy, Structube, a TD branch, and several offices. The building opened in 2012, and the fire alarm system is original.

System Specifications

FACP

The building is protected by a Notifier NFS-320C addressable fire alarm system. The panel is located in the office main entrance vestibule. The system runs Notifier’s FlashScan addressable protocol, and the system coding is temporal.

Annunciators

There is a Notifier LCD-80 annunciator at the Best Buy checkout.

Notification Appliances

All notification appliances are System Sensor “SpectrAlert Advance” P2RA-P horn/strobes (red, wall-mount, no lettering, set to 15cd).

Initiating Devices

Pull Stations

All pull stations are Notifier NBG-12LX addressable dual-action pull stations.

Automatic Detection Devices

There are Notifier FSP-851A addressable photoelectric smoke detectors in the elevator shafts and lobbies, mounted on System Sensor B210LPA bases. The building is fully sprinklered, so no other detectors are visible.

Modules

There are Notifier FMM-1A addressable monitor modules supervising the sprinkler system’s tamper and flow switches. There are Notifier FRM-1A addressable relay modules for elevator recall. There are Notifier ISO-XA isolator modules on the SLC. [[]