Toggle menu
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.

We have switched hosting. Sorry for the recent downtime. :)

Calgary General Hospital: Difference between revisions

From FireAlarmPedia
mNo edit summary
mNo edit summary
Line 6: Line 6:
|-
|-
| FACP: Edwards 6500 <br />System Type: Conventional <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br />Date of last known Upgrade: N/A
| FACP: Edwards 6500 <br />System Type: Conventional <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br />Date of last known Upgrade: N/A
System Coding: 20BPM (first stage)
System Coding: 20BPM (Alert)


March Time (GA) <br />Year Opened: 1977 <br /> Year Demolished: 1998
March Time (Alarm) <br />Year Opened: 1977 <br /> Year Demolished: 1998
|}
|}
The '''Calgary General Hospital''' was a name given to four hospitals in Calgary. The only system known is the Centennial Wing, which had 5 floors. That wing was built in 1977, and retained the original system until being demolished in 1998.
The '''Calgary General Hospital''' was a name given to four hospitals in Calgary. The only system known is the Centennial Wing, located in Building 3 (address: 841 Centre Ave NE, Calgary, AB). which had 5 floors. That wing was built in 1977, and retained the original system until being demolished in 1998.
== Former System Specifications (1977-1998) ==
== Former System Specifications (1977-1998) ==
==== FACP ====
==== FACP ====
The Centennial Wing was protected by an Edwards 6500 conventional fire alarm system. The panel location is unknown. The system was configured for two-stage operation. First stage coding was 20BPM, followed by March Time (120BPM) in general alarm.
The Centennial Wing was protected by an Edwards Custom 6500 conventional fire alarm system. The panel location is unknown. The system was configured for two-stage operation. Alert coding was 20BPM, followed by March Time (120BPM) for the alarm coding.
==== Notification Appliances ====
==== Notification Appliances ====
All notification appliances were Edwards "Adaptabel" 333D single-stroke bells (6" gong). One bell was salvaged by a retired firefighter, and was given to <nowiki>[[User:Alberta Fire Alarms|Alberta Fire Alarms]]</nowiki>, however as of January 2, 2024 it no longer works. You can see it in action in this link: https://www.youtube.com/watch?v=NcoT8Js2K3g
All notification appliances were Edwards "Adaptabel" 333D single-stroke bells (6" gong). One bell was salvaged by a retired firefighter, and was given to [[User:Alberta Fire Alarms|Alberta Fire Alarms]], however it became non-functional in 2023.
 
You can see the bell in action in this link: https://www.youtube.com/watch?v=NcoT8Js2K3g
=== Initiating Devices ===
=== Initiating Devices ===
==== Pull Stations ====
==== Pull Stations ====
All pull stations were Edwards 270-GAO conventional two-stage single-action pull stations. [[User:TwentyThree33|TwentyThree33]] and [[User:Alberta Fire Alarms|Alberta Fire Alarm] each own one pull station from this wing.
All pull stations were Edwards 270-GAO conventional two-stage single-action pull stations. [[User:TwentyThree33|TwentyThree33]] and [[User:Alberta Fire Alarms|Alberta Fire Alarms]] each own one pull station from this wing.
==== Automatic Detection Devices ====
==== Automatic Detection Devices ====
Not available.
There were Edwards 281A fixed/rate-of-rise heat detectors throughout the building.
[[]
[[]

Revision as of 18:41, 19 January 2024

System Specifications
FACP: Edwards 6500
System Type: Conventional
System Line Voltage: 120VAC
NAC Voltage: 24VDC
Date of last known Upgrade: N/A

System Coding: 20BPM (Alert)

March Time (Alarm)
Year Opened: 1977
Year Demolished: 1998

The Calgary General Hospital was a name given to four hospitals in Calgary. The only system known is the Centennial Wing, located in Building 3 (address: 841 Centre Ave NE, Calgary, AB). which had 5 floors. That wing was built in 1977, and retained the original system until being demolished in 1998.

Former System Specifications (1977-1998)

FACP

The Centennial Wing was protected by an Edwards Custom 6500 conventional fire alarm system. The panel location is unknown. The system was configured for two-stage operation. Alert coding was 20BPM, followed by March Time (120BPM) for the alarm coding.

Notification Appliances

All notification appliances were Edwards "Adaptabel" 333D single-stroke bells (6" gong). One bell was salvaged by a retired firefighter, and was given to Alberta Fire Alarms, however it became non-functional in 2023.

You can see the bell in action in this link: https://www.youtube.com/watch?v=NcoT8Js2K3g

Initiating Devices

Pull Stations

All pull stations were Edwards 270-GAO conventional two-stage single-action pull stations. TwentyThree33 and Alberta Fire Alarms each own one pull station from this wing.

Automatic Detection Devices

There were Edwards 281A fixed/rate-of-rise heat detectors throughout the building.