Toggle menu
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.

We have switched hosting. Sorry for the recent downtime. :)

Alberta Fire Alarms' collection: Difference between revisions

From FireAlarmPedia
(DING DONG THE 333D IS DEAD. 1976-2023)
mNo edit summary
Line 51: Line 51:
|N/A
|N/A
|92 dB
|92 dB
|1976
|1977
|From the "Adaptabel" line.
|From the "Adaptabel" line.
Came out of the Calgary General Hospital.
Came out of the Calgary General Hospital.

Revision as of 00:28, 21 January 2024

I have been collecting fire alarms since 2017, and I have a good number of devices.

FACP (Panels)

Model Image Type Zone/Point Capacity NACs Coding Options Power Supply NAC Voltage System Line Voltage Synchronization Support Manufacturing Date Origin
Fire-Lite MS-4 Conventional 4 zones 2 Code-3, continuous 3A (expandable to 6A) 24VFWR 120VAC System Sensor, Wheelock, Gentex December 18, 2015 TwentyThree33.

I have since given it back to him.

Notification Appliances

Model Number Images Quantity Type Voltage Strobe Intensity Loudness Manufacturing Date Notes Origin
Edwards 333D 1 6" Single-Stroke bell 24VDC N/A 92 dB 1977 From the "Adaptabel" line.

Came out of the Calgary General Hospital.

Has been modified to allow easier wiring to panels.

Calgary General Hospital
Unbranded Alarm Bell

from Amazon

1 6" motor bell 24VDC N/A 95 dB 2017 Also known as the "FakeBell"

Works on 9VDC

Amazon
EST 757-5A-T 1 Temporal horn/strobe 20-24VDC 15cd 98/102 dB 1997 From the "Integrity" lineup

Came out of a Walmart in Ontario.

A Walmart in Ontario
Wheelock WM3T-24 1 Weatherproof strobe 18-31VDC 117cd (78cd at -35C) N/A 1993
Mirtone 74306 1 10" motor bell 24VDC N/A 95 dB? Late 1980s-early 1990s Canadian alarms
Edwards/EST (GE) 682-1C 1 Mini-horn 20-24VDC N/A 91 dB? 2008 Thomas Barnable

Pull Stations

Model Number Images Quantity Type Manufacturing Date Notes Origin
Mircom MS-401 2 Conventional, single stage pull station Late 2010s (one 2017) First alarm I ever got. AMRE Supply (overpriced! Just go to Mircom themselves.)
Edwards 270-GAO 2 Two-stage conventional pull station 1977 Came out of the Calgary General Hospital. Non-functional (last worked November 2023) Calgary General Hospital
Simplex 4251-30 1 Dual-action (break glass) conventional T-bar pull station 11th week of 1979 Currently in possession of Yycsfirealarmnimrod, and in use on YYCsFireAlarmNimrod's Basement. Kijiji
Edwards 275-C111 1 Metal conventional pull station late 1980s-early 1990s Canadian Alarms
Mircom MS-401AD 1 Addressable single-stage pull station 2008 Canadian Alarms
Edwards 270-SPO 2 Conventional single-stage pull station 1960s (1)

2009 (1)

Kijiji (1960s), Yycsfirealarmnimrod (2009)
Edwards 270-SPOW 1 Conventional single-stage pull station with Wire Terminals 2011 Canadian Alarms
Simplex 4099-9004 1 Addressable IDNET single-stage T-bar pull station with LED 2018 Canadian Alarms
Pyrotronics MS-51B 1 Conventional, bilingual single action pull station 1980s Branded "Pyr-A-Larm" El Chupacabra
Fire-Lite BG-12 1 Conventional dual-action pull station 2001 El Chupacabra
Mirtone 73303 2 Conventional pull station 1986 Canadian Alarms, Yycsfirealarmnimrod

Automatic Detection Devices

Model Number Images Quantity Type Manufacturing Date Notes Origin
Edwards 281C 1 Fixed Temperature/Rate-of-Rise Heat Detector 1994 Canadian Alarms
Edwards 281B-PL 1 Fixed Temperature/Rate-of-Rise Heat Detector 2010 Came with base Yycsfirealarmnimrod
Mirtone 73340 1 Fixed Temperature/Rate-of-Rise Heat Detector 1998 Paul Huntington
Edwards C2M-PD 1 2-wire, self-diagnostic photoelectric smoke detector 2010 Paul Huntington
System Sensor 2400A 1 direct-wire, photoelectric smoke detector Unknown (1990s-2000s) Thomas Barnable