More actions
(MyProperty now says this was built in 1978) |
mNo edit summary |
||
Line 12: | Line 12: | ||
Strobes Synchronized: Yes<br />Date of last known Upgrade: 2020 <br />Year Opened: 1978 | Strobes Synchronized: Yes<br />Date of last known Upgrade: 2020 <br />Year Opened: 1978 | ||
|} | |} | ||
'''Boston Pizza''' is Canada's largest chain of casual dining restaurants. This particular restaurant is located at 2836 Memorial Drive, in Calgary, Alberta, Canada. The building opened in 1978. Most of the fire alarm system is from the 2000s | '''Boston Pizza''' is Canada's largest chain of casual dining restaurants. This particular restaurant is located at 2836 Memorial Drive, in Calgary, Alberta, Canada. The building opened in 1978. Most of the fire alarm system is from the 2000s. | ||
==System Specifications (2000s-present)== | ==System Specifications (2000s-present)== | ||
====FACP==== | ====FACP==== | ||
The building is protected by a Simplex 4007ES conventional fire alarm system. The panel is located in the main entrance vestibule, and was installed in 2020. The system coding is likely temporal. | The building is protected by a Simplex 4007ES conventional fire alarm system. The panel is located in the main entrance vestibule, and was installed in 2020. The system coding is likely temporal. | ||
The 4007ES likely replaced an EST FireShield FS502G. | |||
====Notification Appliances==== | ====Notification Appliances==== | ||
All notification appliances but one are Edwards 439D-6AWC vibrating bells (6" gong) mounted on Edwards 403-5A-R strobe plates (15cd). The party room has a General Signal MB6-24 motor bell (6" gong) mounted on an Edwards 403-5A-R strobe plate (15cd). | All notification appliances but one are Edwards 439D-6AWC vibrating bells (6" gong) mounted on Edwards 403-5A-R strobe plates (15cd). | ||
The party room has a General Signal MB6-24 motor bell (6" gong) mounted on an Edwards 403-5A-R strobe plate (15cd). | |||
===Initiating Devices=== | ===Initiating Devices=== | ||
====Pull Stations==== | ====Pull Stations==== |
Revision as of 22:59, 6 February 2024
System Specifications |
---|
FACP: Simplex 4007ES
FACP Location: Main Entrance System Coding: Temporal? Strobes Synchronized: Yes |
Boston Pizza is Canada's largest chain of casual dining restaurants. This particular restaurant is located at 2836 Memorial Drive, in Calgary, Alberta, Canada. The building opened in 1978. Most of the fire alarm system is from the 2000s.
System Specifications (2000s-present)
FACP
The building is protected by a Simplex 4007ES conventional fire alarm system. The panel is located in the main entrance vestibule, and was installed in 2020. The system coding is likely temporal.
The 4007ES likely replaced an EST FireShield FS502G.
Notification Appliances
All notification appliances but one are Edwards 439D-6AWC vibrating bells (6" gong) mounted on Edwards 403-5A-R strobe plates (15cd).
The party room has a General Signal MB6-24 motor bell (6" gong) mounted on an Edwards 403-5A-R strobe plate (15cd).
Initiating Devices
Pull Stations
The only known pull station is a Mircom MS-401 conventional single-action pull station. The other pull stations are unknown at this time.
Automatic Detection Devices
None noticed.
Bonus Information
Permit issued for FACP upgrade on August 14th, 2020. Permit description: Fire alarm panel replacement at Memorial Boston Pizza. (Source: Calgary MyProperty) [[]