Calgary Co-op (Dalhousie): Difference between revisions

From FireAlarmPedia
mNo edit summary
Line 17: Line 17:
===Initiating Devices===
===Initiating Devices===
====Pull Stations====
====Pull Stations====
All pull stations but one are Edwards 270-SPO conventional single-action pull stations, with one being original at the front. The rest were installed in 1996.
All pull stations but one are Edwards 270-SPO conventional single-action pull stations, with one being original at the front. The rest were installed in 1996.  


There is one Edwards 275-SPO conventional single-action pull station in the backroom.  
There is one Edwards 275-SPO conventional single-action pull station in the backroom.  
Line 23: Line 23:
None noticed.
None noticed.
== Former System Specifications (1996-2022) ==
== Former System Specifications (1996-2022) ==
{| style="float:right;border:2px solid black"
|-
! Former System Specifications
|-
|
|-
| FACP: EST ESA2000 <br />FACP Location: Unknown <br />System Type: Conventional <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br />System Coding: Continuous <br>Strobes Synchronized: No <br />Date of last known Upgrade: 2010s <br/> Year Installed: 1996 <br />Year Decommissioned: 2022
|}
==== FACP ====
==== FACP ====
The store was most likely protected by an EST 6616 conventional fire alarm system. The panel location was unknown. The system was installed in 1996, and decommissioned in 2022. The system coding was likely continuous.
The store was protected by an EST ESA2000 conventional fire alarm system. The panel location was unknown. The system coding was likely continuous.
===== Annunciators =====
There was an EST annunciator in the health entrance, model to be confirmed.
==== Notification Appliances ====
==== Notification Appliances ====
Most of the notification appliances were Edwards 439D-6AWC vibrating bells (6” gong) on EST 403-5A-R (15cd) strobe plates.  
Most of the notification appliances were Edwards 439D-6AWC vibrating bells (6” gong) on EST 403-5A-R (15cd) strobe plates.  
Line 31: Line 42:
=== Initiating Devices ===
=== Initiating Devices ===
==== Pull Stations ====
==== Pull Stations ====
The pull stations were the Edwards 270-SPO conventional pull stations, and the 275-SPO pull station which are still in use on the iO64.
All pull stations but one are Edwards 270-SPO conventional single-action pull stations, with one being original at the front. The rest were installed in 1996.
 
There is one Edwards 275-SPO conventional single-action pull station in the backroom. 
 
These remain on the current system.  
==== Automatic Detection Devices ====
==== Automatic Detection Devices ====
Not available.
Not available, there was a sprinkler system.
[[]

Revision as of 17:05, 7 April 2024

System Specifications
FACP: Edwards iO64
FACP Location: Unknown
System Type: Conventional
System Line Voltage: 120VAC
NAC Voltage: 24VFWR
System Coding: Temporal
Strobes Synchronized: Yes
Date of last known Upgrade: 2022
Year Opened: 1973

Calgary Co-op is a chain of member-owned grocery stores across Calgary, Alberta, Canada. They have stores throughout the city, and in surrounding towns and cities such as Airdrie and High River. This particular store is located at 5505 Shaganappi Trail Northwest, in Calgary. The store opened in 1973, and the fire alarm system was installed in 2022.

System Specifications (2022-present)

FACP

The building is protected by an Edwards iO64 conventional fire alarm system. The panel location is unknown. The system coding is temporal.

Annunciators

There is an Edwards R-LCD-C annunciator paired with an R-LED annunciator at the Health entrance.

Notification Appliances

All notification appliances are Edwards “Genesis” G4AVRF horn/strobes (red, wall-mount). One is installed on a Wheelock RSSP-24MCW strobe plate, which is disconnected.

Initiating Devices

Pull Stations

All pull stations but one are Edwards 270-SPO conventional single-action pull stations, with one being original at the front. The rest were installed in 1996.

There is one Edwards 275-SPO conventional single-action pull station in the backroom.

Automatic Detection Devices

None noticed.

Former System Specifications (1996-2022)

Former System Specifications
FACP: EST ESA2000
FACP Location: Unknown
System Type: Conventional
System Line Voltage: 120VAC
NAC Voltage: 24VDC
System Coding: Continuous
Strobes Synchronized: No
Date of last known Upgrade: 2010s
Year Installed: 1996
Year Decommissioned: 2022

FACP

The store was protected by an EST ESA2000 conventional fire alarm system. The panel location was unknown. The system coding was likely continuous.

Annunciators

There was an EST annunciator in the health entrance, model to be confirmed.

Notification Appliances

Most of the notification appliances were Edwards 439D-6AWC vibrating bells (6” gong) on EST 403-5A-R (15cd) strobe plates.

There was one Notifier KMS-6-24A motor bell (6” gong) on a Wheelock RSSP-24MCW (red, wall-mount, multi-candela) strobe plate near the entrance as a deficiency replacement. The Wheelock strobe plate still exists, but is disconnected.

Initiating Devices

Pull Stations

All pull stations but one are Edwards 270-SPO conventional single-action pull stations, with one being original at the front. The rest were installed in 1996.

There is one Edwards 275-SPO conventional single-action pull station in the backroom.

These remain on the current system.

Automatic Detection Devices

Not available, there was a sprinkler system.