| FACP: | | FACP: Autocall 4007ES | ||
FACP Location: | FACP Location: Electrical Room?<br />System Type: Addressable <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VDC | ||
System Coding: Temporal | System Coding: Temporal | ||
Strobes Synchronized: SmartSync<br />Date of last known Upgrade: | Strobes Synchronized: Yes, SmartSync<br />Date of last known Upgrade: 2024 <br />Year Opened: 2012 | ||
|} | |} | ||
'''Sobeys''' is a Canadian grocery store chain. This particular location is located at #704 19369 Sheriff King | '''Sobeys''' is a Canadian grocery store chain. This particular location is located at #704 19369 Sheriff King Street SW, in Calgary, Alberta, Canada. The store opened in 2012, and the fire alarm system is partially original. | ||
==System Specifications== | ==System Specifications== | ||
====FACP==== | ====FACP==== | ||
The | The building is protected by an Autocall 4007ES addressable fire alarm system. The panel is likely located in an electrical room. The system runs Autocall's IDNet addressable protocol, and the system coding is temporal. | ||
This panel was installed in 2024 and replaced a Simplex 4008. | |||
===== Annunciators ===== | ===== Annunciators ===== | ||
There is | There is an Autocall A4606-9202 annunciator in the main entrance vestibule. | ||
====Notification Appliances==== | ====Notification Appliances==== | ||
All notification appliances are Simplex "TrueAlert" 4906-9127 horn/strobes (red, wall-mount, set to 15cd). | |||
===Initiating Devices=== | ===Initiating Devices=== | ||
====Pull Stations==== | ====Pull Stations==== | ||
All pull stations are Simplex 4099-9001 addressable single-action pull stations. | |||
====Automatic Detection Devices==== | ====Automatic Detection Devices==== | ||
None noticed. | None noticed. | ||
==== Modules ==== | |||
There are Simplex 4090-9001 addressable monitor modules supervising the sprinkler system's tamper and flow switches. | |||
There are Simplex 4090-9002 addressable relay modules serving various purposes. | |||
Revision as of 16:14, 14 April 2024
System Specifications |
---|
FACP: Autocall 4007ES
FACP Location: Electrical Room? System Coding: Temporal Strobes Synchronized: Yes, SmartSync |
Sobeys is a Canadian grocery store chain. This particular location is located at #704 19369 Sheriff King Street SW, in Calgary, Alberta, Canada. The store opened in 2012, and the fire alarm system is partially original.
System Specifications
FACP
The building is protected by an Autocall 4007ES addressable fire alarm system. The panel is likely located in an electrical room. The system runs Autocall's IDNet addressable protocol, and the system coding is temporal.
This panel was installed in 2024 and replaced a Simplex 4008.
Annunciators
There is an Autocall A4606-9202 annunciator in the main entrance vestibule.
Notification Appliances
All notification appliances are Simplex "TrueAlert" 4906-9127 horn/strobes (red, wall-mount, set to 15cd).
Initiating Devices
Pull Stations
All pull stations are Simplex 4099-9001 addressable single-action pull stations.
Automatic Detection Devices
None noticed.
Modules
There are Simplex 4090-9001 addressable monitor modules supervising the sprinkler system's tamper and flow switches.
There are Simplex 4090-9002 addressable relay modules serving various purposes.
Bonus Information
There are System Sensor "Spectralert Advance" HW (white) remote horns used as door alarms.