Bowen Terrace Building 5: Difference between revisions

From FireAlarmPedia
(honestly surprised this panel hasn't taken a shit)
 
No edit summary
Line 7: Line 7:
| FACP: Edwards 6616 <br />FACP Location: Main Entrance <br />System Type: Conventional <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: Continuous <br />Date of last known Upgrade: 1991 <br />Year Opened: 1965
| FACP: Edwards 6616 <br />FACP Location: Main Entrance <br />System Type: Conventional <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: Continuous <br />Date of last known Upgrade: 1991 <br />Year Opened: 1965
|}
|}
'''Bowen Terrace''' is a group of 5 apartment buildings located in Nanaimo, BC. This page will cover '''Building 5''', which is located at 999 Bowen Rd. It was built in 1965, and the fire alarm system was upgraded in 1991.
'''Bowen Terrace''' is a group of 5 apartment buildings located in Nanaimo, BC. This page will cover '''Building 5''', which is located at 999 Bowen Rd. It was built in 1965, and the fire alarm system was upgraded in 1991.
== System Specifications (1991-present) ==
== System Specifications (1991-present) ==
==== FACP ====
==== FACP ====
The building is protected by an Edwards 6616 conventional fire alarm system. The panel is located at the entrance. The system coding is continuous.
The building is protected by an Edwards 6616 conventional fire alarm system. The panel is located at the entrance. The system coding is continuous.
==== Notification Appliances ====
==== Notification Appliances ====
All notification appliances are Edwards 439D-10AWC vibrating bells (10” gong).
All notification appliances are Edwards 439D-10AWC vibrating bells (10” gong).
=== Initiating Devices ===
=== Initiating Devices ===
==== Pull Stations ====
==== Pull Stations ====
All pull stations are Edwards 275-C111 conventional single-action pull stations.
All pull stations are Edwards 275-C111 conventional single-action pull stations.
==== Automatic Detection Devices ====
==== Automatic Detection Devices ====
There are Edwards 6250C conventional ionization smoke detectors throughout the building. <br> Some areas, and all units have Edwards 281C 135-degree fixed temperature/rate-of-rise heat detectors.
There are Edwards 6250C conventional ionization smoke detectors throughout the building. <br> Some areas, and all units have Edwards 281C 135-degree fixed temperature/rate-of-rise heat detectors.
[[Category:British Columbia]]
[[Category:Residential]]

Revision as of 18:27, 23 May 2024

System Specifications
FACP: Edwards 6616
FACP Location: Main Entrance
System Type: Conventional
System Line Voltage: 120VAC
NAC Voltage: 24VFWR
System Coding: Continuous
Date of last known Upgrade: 1991
Year Opened: 1965

Bowen Terrace is a group of 5 apartment buildings located in Nanaimo, BC. This page will cover Building 5, which is located at 999 Bowen Rd. It was built in 1965, and the fire alarm system was upgraded in 1991.

System Specifications (1991-present)

FACP

The building is protected by an Edwards 6616 conventional fire alarm system. The panel is located at the entrance. The system coding is continuous.

Notification Appliances

All notification appliances are Edwards 439D-10AWC vibrating bells (10” gong).

Initiating Devices

Pull Stations

All pull stations are Edwards 275-C111 conventional single-action pull stations.

Automatic Detection Devices

There are Edwards 6250C conventional ionization smoke detectors throughout the building.
Some areas, and all units have Edwards 281C 135-degree fixed temperature/rate-of-rise heat detectors.