More actions
mNo edit summary |
No edit summary |
||
Line 5: | Line 5: | ||
| | | | ||
|- | |- | ||
|FACP: Edwards iO64 | |FACP: Edwards iO64 <br>FACP Location: Main Entrance Vestibule <br />System Type: Addressable <br />System Line Voltage: 120VAC <br />NAC Voltage: 24VFWR <br />System Coding: Temporal <br>Strobes Synchronized: Yes, Edwards<br />Date of last known Upgrade: N/A <br />Year Opened: 2019 | ||
FACP Location: Main Entrance Vestibule <br />System Type: Addressable <br />System Line Voltage: 120VAC <br />NAC Voltage: 24VFWR <br />System Coding: Temporal | |||
Strobes Synchronized: Yes, Edwards<br />Date of last known Upgrade: N/A <br />Year Opened: 2019 | |||
|}'''CattleBaron Steakhouse''' is a Canadian chain of steakhouse restaurants. This particular restaurant is located at #9100 8650 112 Ave NW, Calgary, Alberta, Canada. The restaurant was built in 2019, and the fire alarm system is original. | |}'''CattleBaron Steakhouse''' is a Canadian chain of steakhouse restaurants. This particular restaurant is located at #9100 8650 112 Ave NW, Calgary, Alberta, Canada. The restaurant was built in 2019, and the fire alarm system is original. | ||
==System Specifications (2019-present)== | ==System Specifications (2019-present)== | ||
Line 22: | Line 19: | ||
====Automatic Detection Devices==== | ====Automatic Detection Devices==== | ||
None noticed. No sprinkler system. | None noticed. No sprinkler system. | ||
==== Modules ==== | ==== Modules ==== | ||
There is an EST SIGA-CT1 addressable monitor module supervising the kitchen suppression system. | There is an EST SIGA-CT1 addressable monitor module supervising the kitchen suppression system. | ||
[[Category:Calgary]] | |||
[[Category:Restaurants]] |
Revision as of 19:05, 23 May 2024
System Specifications |
---|
FACP: Edwards iO64 FACP Location: Main Entrance Vestibule System Type: Addressable System Line Voltage: 120VAC NAC Voltage: 24VFWR System Coding: Temporal Strobes Synchronized: Yes, Edwards Date of last known Upgrade: N/A Year Opened: 2019 |
CattleBaron Steakhouse is a Canadian chain of steakhouse restaurants. This particular restaurant is located at #9100 8650 112 Ave NW, Calgary, Alberta, Canada. The restaurant was built in 2019, and the fire alarm system is original.
System Specifications (2019-present)
FACP
The building is protected by an Edwards iO64 addressable fire alarm system. The panel is located in the main entrance vestibule. The system runs Edwards' Signature addressable protocol; the system coding is temporal.
Notification Appliances
All indoor notification appliances are Edwards “Genesis” GC-HDVM horn/strobes (white, ceiling-mount, no lettering).
There is an Edwards CS405-7A-T weatherproof remote strobe (red, 15/75cd) by the entrance and an Edwards WG4RN-HVMC weatherproof horn/strobe (red, no lettering, set to 75cd) outside the patio for outdoor notification.
Initiating Devices
Pull Stations
All pull stations are EST SIGA-270 addressable single-action pull stations.
Automatic Detection Devices
None noticed. No sprinkler system.
Modules
There is an EST SIGA-CT1 addressable monitor module supervising the kitchen suppression system.