| FACP: None <br />System Type: 120V Hardwired <br /> System Line Voltage: 120VAC <br /> System Coding: Continuous <br />Date of last known Upgrade: 2010s <br />Year Opened: 1970 | | FACP: None <br />System Type: 120V Hardwired <br /> System Line Voltage: 120VAC <br /> System Coding: Continuous <br />Date of last known Upgrade: 2010s <br />Year Opened: 1970 | ||
|} | |} | ||
The '''Foothills Little League Clubhouse''' is a small building located at 2255 Crowchild Trail, in Calgary, AB. The building was built in 1970, and the fire alarm system is mostly original. | |||
The '''Foothills Little League Clubhouse''' is a small building located at 2255 Crowchild Trail, in Calgary, AB. | |||
==System Specifications== | ==System Specifications== | ||
====FACP==== | ====FACP==== | ||
The building is protected by a hardwired 120VAC fire alarm system, therefore there is no panel. | The building is protected by a hardwired 120VAC fire alarm system, therefore there is no panel. | ||
====Notification Appliances==== | ====Notification Appliances==== | ||
The only notification appliance is a Simplex 4090-2 vibrating bell in the stairwell (6” gong). | The only notification appliance is a Simplex 4090-2 vibrating bell in the stairwell (6” gong). | ||
===Initiating Devices=== | ===Initiating Devices=== | ||
====Pull Stations==== | ====Pull Stations==== | ||
The only pull station is an Edwards 270-SPO conventional single-action pull station in the lobby. | The only pull station is an Edwards 270-SPO conventional single-action pull station in the lobby. | ||
====Automatic Detection Devices==== | ====Automatic Detection Devices==== | ||
There are System Sensor 5601A conventional 135°F fixed-temperature/rate-of-rise heat detectors in several storage rooms. | There are System Sensor 5601A conventional 135°F fixed-temperature/rate-of-rise heat detectors in several storage rooms. <br>There is an Edwards 281C conventional 135°F fixed-temperature/rate-of-rise heat detector in the furnace room. | ||
[[Category:Calgary]] | |||
[[Category:Stadiums]] |
Latest revision as of 15:20, 25 May 2024
System Specifications |
---|
FACP: None System Type: 120V Hardwired System Line Voltage: 120VAC System Coding: Continuous Date of last known Upgrade: 2010s Year Opened: 1970 |
The Foothills Little League Clubhouse is a small building located at 2255 Crowchild Trail, in Calgary, AB. The building was built in 1970, and the fire alarm system is mostly original.
System Specifications[edit | edit source]
FACP[edit | edit source]
The building is protected by a hardwired 120VAC fire alarm system, therefore there is no panel.
Notification Appliances[edit | edit source]
The only notification appliance is a Simplex 4090-2 vibrating bell in the stairwell (6” gong).
Initiating Devices[edit | edit source]
Pull Stations[edit | edit source]
The only pull station is an Edwards 270-SPO conventional single-action pull station in the lobby.
Automatic Detection Devices[edit | edit source]
There are System Sensor 5601A conventional 135°F fixed-temperature/rate-of-rise heat detectors in several storage rooms.
There is an Edwards 281C conventional 135°F fixed-temperature/rate-of-rise heat detector in the furnace room.