Misericordia Community Hospital: Difference between revisions

From FireAlarmPedia
(Cerberus)
 
No edit summary
Line 7: Line 7:
| FACP: Cerberus Pyrotronics MXLV <br />FACP Location: Main Lobby <br />System Type: Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 70.7VRMS <br />System Coding: Unknown <br>Strobes Synchronized: N/A <br />Date of last known Upgrade: 1999 <br />Year Opened: 1969, 1992
| FACP: Cerberus Pyrotronics MXLV <br />FACP Location: Main Lobby <br />System Type: Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 70.7VRMS <br />System Coding: Unknown <br>Strobes Synchronized: N/A <br />Date of last known Upgrade: 1999 <br />Year Opened: 1969, 1992
|}
|}
 
'''Misericordia Community Hospital''' is a general hospital located at 16940 87 Avenue NW, in Edmonton, Alberta, Canada. The hospital is jointly owned and operated by Covenant Health and Alberta Health Services. The hospital was built in 1969, and expanded in 1992. The fire alarm system was upgraded in 1999.
'''Misericordia Community Hospital''' is a general hospital located at 16940 87 Avenue NW, in Edmonton, Alberta, Canada. The hospital is jointly owned and operated by Covenant Health and Alberta Health Services. The hospital was built in 1969, and expanded in 1992. The fire alarm system was upgraded in 1999.
 
==System Specifications (1999-present)==
==System Specifications (1999-present)==
Please note that some system details are unconfirmed. This page should not be used for official purposes.
Please note that some system details are unconfirmed. This page should not be used for official purposes.
====FACP====
====FACP====
The building is protected by a Cerberus Pyrotronics MXLV addressable fire alarm system. This is a networked system with several nodes; one node is located in the main lobby. The system runs Cerberus’ FirePrint addressable protocol, and is equipped with voice evacuation. The system is configured for two-stage operation, however the messages and/or tones are unknown at this time.
The building is protected by a Cerberus Pyrotronics MXLV addressable fire alarm system. This is a networked system with several nodes; one node is located in the main lobby. The system runs Cerberus’ FirePrint addressable protocol, and is equipped with voice evacuation. The system is configured for two-stage operation, however the messages and/or tones are unknown at this time.
 
=====Annunciators=====
=====Annunciators=====
There are Cerberus Pyrotronics RCC-1 LCD annunciators at all nurse’s stations.
There are Cerberus Pyrotronics RCC-1 LCD annunciators at all nurse’s stations.
====Notification Appliances====
====Notification Appliances====
All notification appliances are Arnscott AS4011 remote speakers (white, ceiling-mount, 4” round, 70V).
All notification appliances are Arnscott AS4011 remote speakers (white, ceiling-mount, 4” round, 70V).
===Initiating Devices===
===Initiating Devices===
====Pull Stations====
====Pull Stations====
All pull stations are Cerberus Pyrotronics MSI-30B addressable two-stage single-action pull stations.
All pull stations are Cerberus Pyrotronics MSI-30B addressable two-stage single-action pull stations.
====Automatic Detection Devices====
====Automatic Detection Devices====
There are Cerberus Pyrotronics ILP-1 addressable photoelectric smoke detectors throughout the building.
There are Cerberus Pyrotronics ILP-1 addressable photoelectric smoke detectors throughout the building.
====Modules====
====Modules====
There are Cerberus Pyrotronics TRI-B6 addressable monitor modules supervising the sprinkler system’s tamper and flow switches.
There are Cerberus Pyrotronics TRI-B6 addressable monitor modules supervising the sprinkler system’s tamper and flow switches.
[[Category:Edmonton]]
[[Category:Healthcare]]

Revision as of 20:20, 25 May 2024

System Specifications
FACP: Cerberus Pyrotronics MXLV
FACP Location: Main Lobby
System Type: Addressable
System Line Voltage: 120VAC
NAC Voltage: 70.7VRMS
System Coding: Unknown
Strobes Synchronized: N/A
Date of last known Upgrade: 1999
Year Opened: 1969, 1992

Misericordia Community Hospital is a general hospital located at 16940 87 Avenue NW, in Edmonton, Alberta, Canada. The hospital is jointly owned and operated by Covenant Health and Alberta Health Services. The hospital was built in 1969, and expanded in 1992. The fire alarm system was upgraded in 1999.

System Specifications (1999-present)

Please note that some system details are unconfirmed. This page should not be used for official purposes.

FACP

The building is protected by a Cerberus Pyrotronics MXLV addressable fire alarm system. This is a networked system with several nodes; one node is located in the main lobby. The system runs Cerberus’ FirePrint addressable protocol, and is equipped with voice evacuation. The system is configured for two-stage operation, however the messages and/or tones are unknown at this time.

Annunciators

There are Cerberus Pyrotronics RCC-1 LCD annunciators at all nurse’s stations.

Notification Appliances

All notification appliances are Arnscott AS4011 remote speakers (white, ceiling-mount, 4” round, 70V).

Initiating Devices

Pull Stations

All pull stations are Cerberus Pyrotronics MSI-30B addressable two-stage single-action pull stations.

Automatic Detection Devices

There are Cerberus Pyrotronics ILP-1 addressable photoelectric smoke detectors throughout the building.

Modules

There are Cerberus Pyrotronics TRI-B6 addressable monitor modules supervising the sprinkler system’s tamper and flow switches.