Toggle menu
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.

We have switched hosting. Sorry for the recent downtime. :)

OMSI: Difference between revisions

From FireAlarmPedia
No edit summary
No edit summary
Line 7: Line 7:
| FACP: Simplex 4100ES <br /> FACP Location: Main Entrance <br />System Type: Addressable <br /> System Line Voltage: 120VAC<br />NAC Voltage: 25VRMS (Audible) <br> 24VDC (Visual) <br /> System Coding: Slow Whoop + Message <br> Strobes Synchronized: No <br />Date of last known Upgrade: 2022 <br />Year Opened: 1992
| FACP: Simplex 4100ES <br /> FACP Location: Main Entrance <br />System Type: Addressable <br /> System Line Voltage: 120VAC<br />NAC Voltage: 25VRMS (Audible) <br> 24VDC (Visual) <br /> System Coding: Slow Whoop + Message <br> Strobes Synchronized: No <br />Date of last known Upgrade: 2022 <br />Year Opened: 1992
|}
|}
 
The '''Oregon Museum of Science & Industry''' is a large science museum located at 1945 SE Water Avenue, in Portland, Oregon, USA. The museum opened in 1992, and the fire alarm system is original excluding the main FACP.
The '''Oregon Museum of Science & Industry''' is a large science museum located at 1945 SE Water Avenue, in Portland, Oregon, USA. The museum opened in 1992, and the fire alarm system is original excluding the main FACP.
 
==System Specifications==
==System Specifications==
====FACP====
====FACP====
The building is protected by a Simplex 4100ES addressable fire alarm system. The panel is located in the main entrance vestibule. The system runs Simplex’s MAPNET II addressable protocol, and is equipped with voice evacuation. The evacuation tone is slow whoop, followed by a male message. See the script below.
The building is protected by a Simplex 4100ES addressable fire alarm system. The panel is located in the main entrance vestibule. The system runs Simplex’s MAPNET II addressable protocol, and is equipped with voice evacuation. The evacuation tone is slow whoop, followed by a male message. See the script below.
 
====Notification Appliances====
====Notification Appliances====
Most notification appliances are Wheelock ET-1090-24-WS-CFW speaker/strobes (white, ceiling-mount, 25V, 1.5cd). Some areas have Wheelock E7025-WS-24 speaker/strobes (red, wall-mount, 25V, 1.5cd).
Most notification appliances are Wheelock ET-1090-24-WS-CFW speaker/strobes (white, ceiling-mount, 25V, 1.5cd). Some areas have Wheelock E7025-WS-24 speaker/strobes (red, wall-mount, 25V, 1.5cd).
 
===Initiating Devices===
===Initiating Devices===
====Pull Stations====
====Pull Stations====
All pull stations are Simplex 2099-9795 addressable single-action pull stations.
All pull stations are Simplex 2099-9795 addressable single-action pull stations.
====Automatic Detection Devices====
====Automatic Detection Devices====
Not currently known.
Not currently known.
==Message Script==
==Message Script==
There is a fire emergency in the building. You are to leave the building by the nearest exit. Do not use the elevators.
There is a fire emergency in the building. You are to leave the building by the nearest exit. Do not use the elevators.
[[Category:Facilities]]
[[Category:Facilities]]
[[Category:Oregon]]
[[Category:Museums]]

Revision as of 16:22, 26 May 2024

System Specifications
FACP: Simplex 4100ES
FACP Location: Main Entrance
System Type: Addressable
System Line Voltage: 120VAC
NAC Voltage: 25VRMS (Audible)
24VDC (Visual)
System Coding: Slow Whoop + Message
Strobes Synchronized: No
Date of last known Upgrade: 2022
Year Opened: 1992

The Oregon Museum of Science & Industry is a large science museum located at 1945 SE Water Avenue, in Portland, Oregon, USA. The museum opened in 1992, and the fire alarm system is original excluding the main FACP.

System Specifications

FACP

The building is protected by a Simplex 4100ES addressable fire alarm system. The panel is located in the main entrance vestibule. The system runs Simplex’s MAPNET II addressable protocol, and is equipped with voice evacuation. The evacuation tone is slow whoop, followed by a male message. See the script below.

Notification Appliances

Most notification appliances are Wheelock ET-1090-24-WS-CFW speaker/strobes (white, ceiling-mount, 25V, 1.5cd). Some areas have Wheelock E7025-WS-24 speaker/strobes (red, wall-mount, 25V, 1.5cd).

Initiating Devices

Pull Stations

All pull stations are Simplex 2099-9795 addressable single-action pull stations.

Automatic Detection Devices

Not currently known.

Message Script

There is a fire emergency in the building. You are to leave the building by the nearest exit. Do not use the elevators.