Toggle menu
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.

We have switched hosting. Sorry for the recent downtime. :)

Royal Tyrrell Museum: Difference between revisions

From FireAlarmPedia
(Cleaned up the page.)
No edit summary
Line 1: Line 1:
'''Royal Tyrrell Museum''' is a paleontology and dinosaur museum located at 1500 N Dinosaur Trail, in Drumheller, Alberta, Canada. It is Canada's only museum exclusively showcasing prehistoric life. The museum opened in 1985, and received total fire alarm system upgrades in 2003 and 2016.
'''Royal Tyrrell Museum''' is a paleontology and dinosaur museum located at 1500 N Dinosaur Trail, in Drumheller, Alberta, Canada. It is Canada's only museum exclusively showcasing prehistoric life. The museum opened in 1985, and received total fire alarm system upgrades in 2003 and 2016.
{| style="float:right;border:2px solid black"
{| style="float:right;border:2px solid black"
|-
|-
Line 35: Line 35:
|  
|  
|-
|-
| FACP: Siemens MXL <br>FACP Location: Near Main Entrance<br />System Type: Addressable (Two-Stage) <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br>System Coding: 20BPM (Alert) <br>Temporal (Alarm) <br>Strobes Synchronized: Yes, Siemens<br />Date of last known Upgrade: N/A <br>Year Installed: 2003<br />Year Decommissioned: 2016
| FACP: Siemens MXL <br>FACP Location: Near Main Entrance<br />System Type: Addressable (Two-Stage) <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br>System Coding: 20BPM (Alert) <br>Temporal (Alarm) <br>Strobes Synchronized: Yes, Siemens<br />Date of last known Upgrade: N/A <br>Year Installed: 2003<br />Year Decommissioned: 2016
|}
|}
==== FACP ====
==== FACP ====
Line 52: Line 52:
[[Category:Facilities]]
[[Category:Facilities]]
[[Category:Facilities]]
[[Category:Facilities]]
[[Category:Alberta]]

Revision as of 17:25, 26 May 2024

Royal Tyrrell Museum is a paleontology and dinosaur museum located at 1500 N Dinosaur Trail, in Drumheller, Alberta, Canada. It is Canada's only museum exclusively showcasing prehistoric life. The museum opened in 1985, and received total fire alarm system upgrades in 2003 and 2016.

System Specifications
FACP: Edwards EST3
FACP Location: Main Entrance
System Type: Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VDC
System Coding: Temporal
Strobes Synchronized: Yes, Genesis
Date of last known Upgrade: 2016
Year Opened: 1985

System Specifications (2016-present)

FACP

The building is protected by an Edwards EST3 addressable fire alarm system. The panel is located in the lobby. It is equipped with the LCDXL1 display and an ENVOY graphic annunciator. The system runs Edwards' Signature addressable protocol, and the system coding is temporal.

Notification Appliances

Most notification appliances are EST "Genesis" G1R-HDVM horn/strobes (red, wall-mount, no marking, set to 15cd), mounted on EST G1RT-FIRE trim plates; others are not mounted on trim plates.

The Cretaceous Gardens have Edwards WG4RN-HVMC weatherproof horn/strobes (red, no marking, set to 60cd).

For outdoor notification, there is an EST CS405-7A-T (red, 15/75cd) weatherproof remote strobe by the main entrance.

Initiating Devices

Pull Stations

All pull stations are EST SIGC-270B addressable bilingual single-action pull stations.

Automatic Detection Devices

There are EST SIGA2-PS addressable photoelectric smoke detectors in some areas, mounted on SIGA-SB bases.

The air handling units have EST "SuperDuct" SIGA-SD addressable photoelectric duct smoke detectors.

There is also a sprinkler system.

Modules

There are EST SIGA-CT1 addressable monitor modules supervising the sprinkler system's tamper and flow switches.

There are also EST SIGA-CR relay modules serving various purposes.

Former System Specifications (2003-2016)

System Specifications
FACP: Siemens MXL
FACP Location: Near Main Entrance
System Type: Addressable (Two-Stage)
System Line Voltage: 120VAC
NAC Voltage: 24VDC
System Coding: 20BPM (Alert)
Temporal (Alarm)
Strobes Synchronized: Yes, Siemens
Date of last known Upgrade: N/A
Year Installed: 2003
Year Decommissioned: 2016

FACP

The building was protected by a Siemens MXL addressable fire alarm system. The panel was located near the main entrance. The system ran Siemens' FirePrint addressable protocol, and was configured for two stage operation. The alert signal coding was 20BPM, and the alarm signal was temporal.

Notification Appliances

All notification appliances were Siemens U-MMT-MCS-W-B (white, bilingual, wall-mount, multi-candela) multi tone horn/strobes. They were likely set to the horn tone.

Initiating Devices

Pull Stations

All pull stations were Siemens MSI-30B addressable two-stage single-action pull stations.

Automatic Detection Devices

None noticed. There was a sprinkler system.

Modules

There were Siemens TRI-M addressable monitor modules supervising the sprinkler system's tamper and flow switches.

Bonus Information

Above the outdoor strobe, there is an Edwards "Adaptabel" 333D single-stroke bell (6" gong), left over from the original Edwards 6500 system. It is disconnected.