| FACP: EST QuickStart QS1? <br /> FACP Location: Unknown <br />System Type: Addressable <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br /> System Coding: Temporal <br> Strobes Synchronized: Yes, EST <br />Date of last known Upgrade: N/A <br />Year Opened: 2006
| FACP: EST QuickStart QS1? <br /> FACP Location: Unknown <br />System Type: Addressable <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br /> System Coding: Temporal <br> Strobes Synchronized: Yes, EST <br />Date of last known Upgrade: N/A <br />Year Opened: 2006
|}
|}
 
'''Western Budget Inn & Suites Leduc''' is a budget hotel located at 7712 Sparrow Drive, in Leduc, Alberta, Canada. The hotel opened in 2006, and the fire alarm system is original.
'''Western Budget Inn & Suites Leduc''' is a budget hotel located at 7712 Sparrow Drive, in Leduc, Alberta, Canada. The hotel opened in 2006, and the fire alarm system is original.
 
==System Specifications==
==System Specifications==
Please note that the FACP model is unconfirmed, and is assumed based on the initiating devices.
Please note that the FACP model is unconfirmed, and is assumed based on the initiating devices.
====FACP====
====FACP====
The building is protected by an EST QuickStart QS1 addressable fire alarm system. The panel location is unknown. The system runs EST’s Signature addressable protocol, and the system coding is temporal.
The building is protected by an EST QuickStart QS1 addressable fire alarm system. The panel location is unknown. The system runs EST’s Signature addressable protocol, and the system coding is temporal.
 
====Notification Appliances====
====Notification Appliances====
=====Common Areas=====
=====Common Areas=====
There are EST “Genesis” G1R-HDVM horn/strobes (red, wall-mount, no lettering, set to 15cd) throughout the common areas.
There are EST “Genesis” G1R-HDVM horn/strobes (red, wall-mount, no lettering, set to 15cd) throughout the common areas.
=====Guest Rooms=====
=====Guest Rooms=====
All guest rooms have Edwards 683-1C silenceable mini-horns (white, wall-mount). Some guest rooms have Edwards “Genesis” G1-VM remote strobes (white, wall-mount, no lettering, set to 15cd), and the remaining rooms have Edwards “Integrity” 202-8A-TW remote strobes (white, wall-mount, 110cd).
All guest rooms have Edwards 683-1C silenceable mini-horns (white, wall-mount). Some guest rooms have Edwards “Genesis” G1-VM remote strobes (white, wall-mount, no lettering, set to 15cd), and the remaining rooms have Edwards “Integrity” 202-8A-TW remote strobes (white, wall-mount, 110cd).
 
===Initiating Devices===
===Initiating Devices===
====Pull Stations====
====Pull Stations====
All pull stations are EST SIGA-270 addressable single-action pull stations.
All pull stations are EST SIGA-270 addressable single-action pull stations.
====Automatic Detection Devices====
====Automatic Detection Devices====
There are EST SIGA-PS addressable photoelectric smoke detectors throughout the hotel’s common areas, mounted on EST SIGA-SB bases.
There are EST SIGA-PS addressable photoelectric smoke detectors throughout the hotel’s common areas, mounted on EST SIGA-SB bases.
[[Category:Facilities]]
[[Category:Facilities]]
[[Category:Hotels]]
[[Category:Leduc]]

Revision as of 09:49, 28 May 2024

System Specifications
FACP: EST QuickStart QS1?
FACP Location: Unknown
System Type: Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VFWR
System Coding: Temporal
Strobes Synchronized: Yes, EST
Date of last known Upgrade: N/A
Year Opened: 2006

Western Budget Inn & Suites Leduc is a budget hotel located at 7712 Sparrow Drive, in Leduc, Alberta, Canada. The hotel opened in 2006, and the fire alarm system is original.

System Specifications

Please note that the FACP model is unconfirmed, and is assumed based on the initiating devices.

FACP

The building is protected by an EST QuickStart QS1 addressable fire alarm system. The panel location is unknown. The system runs EST’s Signature addressable protocol, and the system coding is temporal.

Notification Appliances

Common Areas

There are EST “Genesis” G1R-HDVM horn/strobes (red, wall-mount, no lettering, set to 15cd) throughout the common areas.

Guest Rooms

All guest rooms have Edwards 683-1C silenceable mini-horns (white, wall-mount). Some guest rooms have Edwards “Genesis” G1-VM remote strobes (white, wall-mount, no lettering, set to 15cd), and the remaining rooms have Edwards “Integrity” 202-8A-TW remote strobes (white, wall-mount, 110cd).

Initiating Devices

Pull Stations

All pull stations are EST SIGA-270 addressable single-action pull stations.

Automatic Detection Devices