==New Garage Installation Photos==
==New Garage Installation Photos==
<gallery mode=slideshow>
2222gWiring12272020.jpg|The panel as it looked on December 27th, 2020 at this point the wiring for the back pull station and the Notifier bell had not yet been run.
2222gManDoorBG12.jpg|The present day BG-12 (a replacement in a period specific setting) located near the man door.
2222gPullStation2.jpg|The location for the "original" period specific pull station. (To be installed sometime in early 2020) beside the garage door.
2222g4W-B.jpg|The 4W-B (yes, not the Canadian model) positioned adjacent to the door opener.
2222gSTWCeol.jpg|The location for the last STWC and the last device in the Wheelock circuit located close to the garage door.
2222gstwc2.jpg|The second STWC in the Wheelock circuit located near the furnace.
2222gstwc1.jpg|The first Strobe in the Wheelock circuit wired directly after the RSSP
</gallery>

Revision as of 22:54, 27 December 2020

The original Twentytwo22's Garage was a small residential garage in Sundance, built in 1994. The system was owned by User:Twentytwo22 As of September 1st, 2020 Twentytwo22 has moved to a location in Glenbrook.
The new garage was built in 1966 and plans to add period specific Initiating Devices (except automatic detection) and Notification Appliances are considered.

System Specifications

  • Note: The system is currently getting installed, so it is not complete.

FACP

The fire alarm panel is an EST Quickstart QSC (conventional) with the PS6 power supply card and one ZB16 card.
Most of the zones were unused and simply have a resistor across them due to the small size of the garage. The panel was transferred over from the old garage. The panel will be setup as a timed two-stage system with an "evacuate" key switch to force the system into second stage before the 5 minute timer ends. In first stage the panel will do 20bpm (slow march) and 120bpm March time in second stage.

Notification Appliances

The notification appliances consist of a Simplex 2901-9722 10" motor bell. Twentytwo22 has plans install a Wheelock RSSP-2415W-FR strobe plate, a Notifier KMS-10-24A motor bell, and three Wheelock "Exceder" STWC (white, ceiling) remote strobes.

Initiating Devices

Pull Stations

There are no pull stations installed yet, however Twentytwo22 plans to install an older Simplex 4251-series pull station.

Automatic Detection Devices

There was is automatic detection device, a System Sensor C4W-B (i3) smoke detector.

System Specifications (Original Garage)

FACP

The fire alarm panel was an EST Quickstart QSC (conventional) with the PS6 power supply card and one ZB16 card. Most of the Zones were unused and simply have a resistor across them due to the small size of the garage. Now in use on the new garage.

Notification Appliances

The two notification appliances were a Simplex 2901-9722 10" motor bell installed to accommodate owner preference and one EST Genesis G1-VM (white, no fire marking) remote strobe. The 2901-9722 was previously used in a school, and is still in use on the new garage. Formerly, there was a Gentex "Commander 3" GEC3-24WR (red, wall) horn/strobe.

Initiating Devices

Pull Stations

The pull stations consisted of one Chinese Pull Station, one Fire-Lite BG-12L and one GE-branded Edwards 270-SPO.

Automatic Detection Devices

There was one automatic detection device, a System Sensor C4W-B (i3) smoke detector that replaced a two wire equivalent. (C2W-BA)