More actions
System Specifications |
---|
FACP: Edwards iO1000
FACP Location: Main Entrance System Coding: Temporal Strobes Synchronized: Yes, Genesis |
No Frills is a Canadian chain of discount supermarkets. They have over 200 stores in 9 provinces, and are owned by Loblaws. This particular store is located at 1050 Yankee Valley Crossing in Airdrie, Alberta, and was likely built in 2000 as Extra Foods, and became No Frills in 2009. The fire alarm system was upgraded in 2022.
System Specifications
FACP
The store is protected by an Edwards iO1000 conventional fire alarm system. The panel is located in the main entrance vestibule. The system runs Edwards' Signature addressable protocol, and the system coding is temporal.
Notification Appliances
All notification appliances are Edwards "Genesis" G1AVRF horn/strobes (red, wall-mount, FIRE marking, set to 15cd).
Initiating Devices
Pull Stations
All pull stations are EST SIGA-270 addressable single-action pull stations, leftover from the original system.
Automatic Detection Devices
None noticed. There is a sprinkler system.
Modules
There are EST SIGA-WTM addressable monitor modules supervising the sprinkler system's tamper and flow switches.
EOLs
There are Edwards EOL-P1 end-of-line resistor plates on all sprinkler and signal circuits.
Former System Specifications (2000-2022)
Former System Specifications |
---|
FACP: Edwards EST2 FACP Location: Main Entrance Vestibule System Type: Single-Stage Addressable System Line Voltage: 120VAC NAC Voltage: 24VDC System Coding: Continuous Strobes Synchronized: No Date of last known Upgrade: N/A Year Installed: 2000 Year Decommissioned: 2022 |
FACP
The building was protected by an Edwards EST2 addressable fire alarm system. The panel was located in the main entrance vestibule. The system ran Edwards' Signature addressable protocol, and the system coding was continuous.
Notification Appliances
All notification appliances were General Signal MB10-24 motor bells (10" gong) mounted on Edwards 403-5A-R strobe plates (15cd).
Initiating Devices
Pull Stations
All pull stations were EST SIGA-270 addressable single-action pull stations, these are still in use.
Automatic Detection Devices
None noticed. There is a sprinkler system.
Modules
There were EST SIGA-WTM addressable monitor modules supervising the sprinkler system's tamper and flow switches, still in service.
EOLs
There are Edwards EOL-P1 end-of-line resistor plates on all sprinkler and signal circuits.