Toggle menu
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.

We have switched hosting. Sorry for the recent downtime. :)

Oakridge Mall

From FireAlarmPedia
Revision as of 14:03, 29 November 2024 by TwentyThree33 (talk | contribs) (Simp)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
System Specifications
FACP: Simplex 4010
FACP Location: Near Co-op Customer Service
System Type: Single-StageAddressable
System Line Voltage: 120VAC
NAC Voltage: 24VDC
System Coding: Temporal
Strobes Synchronized: Yes, Wheelock
Date of last known Upgrade: Circa 2004
Year Opened: 1976

Oakridge Mall was a small shopping centre located at 2580 Southland Drive Southwest, in Calgary, Alberta, Canada. The mall's primary tenants were Calgary Co-op and Dollar Store. The mall opened in 1976, and the fire alarm system was fully replaced in the 2000s.

The Calgary Co-op store still exists, however it is slated to be demolished in the near future. This system is still in service in the store.

System Specifications

FACP

The building is protected by a Simplex 4010 addressable fire alarm system. The panel is located near the Co-op customer service desk. The system runs Simplex's IDNet addressable protocol, and the system coding is temporal.

Annunciators

There were Simplex 4606-9102 LCD annunciators at every mall corridor entrance.

Notification Appliances

Co-op

All notification appliances are Wheelock MB-G10-24 motor bells (10" gong) mounted on Wheelock RSSP-24MCW strobe plates (set to 15cd).

Main Mall

All notification appliances were Simplex 2901-9724 motor bells (10" gong) mounted on Wheelock RSSP-24MCW strobe plates (set to 15cd).

Initiating Devices

Pull Stations

All pull stations are Simplex 4099-9001 addressable single-action pull stations.

Automatic Detection Devices

None noticed.