Max Bell Centre

From FireAlarmPedia
Revision as of 10:19, 3 February 2022 by TwentyThree33 (talk | contribs) (Added the new system. Fuck the city for not letting us get the old alarms. They should rot in hell for that.)
System Specifications
FACP: Mircom FX-2000
System Type:Addressable
System Line Voltage: 120VAC
NAC Voltage:24VFWR
Date of last known Upgrade: 2018 (potential upgrade this year)
Year Opened: 1971, 2007

Max Bell Centre (also called Max Bell Arena) is an ice hockey arena in SE Calgary, located in Radisson Heights. It is located off of Barlow Trail SE. It was built in 1971, and had it's second arena built in 2007. It also hosted the 1988 Winter Olympics. The current fire alarm system is from 2021.

System Specifications

FACP

The arena is protected by a Simplex 4100ES addressable fire alarm system. The panel location is unknown, but has been confirmed by an annunciator. The system runs Simplex's IDNet addressable protocol, and does code 3 in alarm.

Annunciators

There is a Simplex 4100-9315 Operator Interface near the main entrance.

Notification Appliances

Most notification appliances are Simplex "TrueAlert" 4906-9129 SmartSync horn/strobes (white, wall-mount). The lobby has Simplex "TrueAlert" 4906-9130 SmartSync horn/strobes (white, ceiling-mount).

Initiating Devices

Pull Stations

All pull stations are Simplex 4099-9004 addressable single-action pull stations.

Automatic Detection Devices

There are Simplex 4098-9714 addressable photoelectric smoke detectors throughout the arenas.

System Specifications (previous system)

FACP

The fire alarm panel was a Mircom FX-2000. It is confirmed due to an annunciator located at the entrance, but the main panel was not visible; it was in some office. The FX-2000 was installed in 2018, replacing the older FX-2000 from the expansion in 2007.

Notification Appliances

The notification appliances consisted of Notifier KMS-6-24A motor bells on Mircom strobe plates in Ken Bracko arena, and Mircom BL-10B motor bells on Mircom strobe plates in Max Bell #2. The dressing room hallway of MBII has Mircom BL-6A motor bells on Mircom strobe plates. There is also an Edwards 439D-10AWC vibrating bell (installed sometime around 2017, due to the white label) in a dressing room. The strobe plates' model numbers are yet to be confirmed.

Initiating Devices

Pull Stations

The pull stations consisted of Mircom MS-401AD addressable pull stations from 2007.

Automatic Detection Devices

There were several Mircom MIX-2251B addressable photoelectric smoke detectors throughout the building.