Toggle menu
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.

We have switched hosting. Sorry for the recent downtime. :)

655 Meredith Road NE, Calgary

From FireAlarmPedia
System Specifications
FACP: None
System Type: 120V Hardwired
System Line Voltage: 120VAC
NAC Voltage: 120VAC

System Coding: Continuous
Date of last known Upgrade: 1990s
Year Opened: 1972

655 Meredith Road NE is a 3-story low rise apartment complex in the Bridgeland neighborhood of Calgary, Alberta, Canada. It can be seen off of Memorial Drive NE. The condominium was built in 1972, and the fire alarm system is original.

System Specifications

FACP

The building is protected by a 120V hardwired fire alarm system. There is no FACP for this system; all devices operate off 120VAC.

Notification Appliances

All notification appliances are Edwards "Durabel" 6000D vibrating bells (6" gong). There is one bell per floor.

Initiating Devices

Pull Stations

All pull stations are Edwards 270-SPO conventional single-action pull stations.

Automatic Detection Devices

There are American Sensors ESA5011 ionization 120V smoke detectors installed in all corridors. There is one detector per floor. [[] [[]