Toggle menu
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.

We have switched hosting. Sorry for the recent downtime. :)

Grand Theatre (London)

From FireAlarmPedia
Revision as of 16:17, 28 September 2024 by TwentyThree33 (talk | contribs) (AWWWWWWWWWWWWditoriums)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
System Specifications
FACP: Mircom FX-2000
FACP Location: Unknown
System Type: Two-Stage Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VFWR
System Coding: 20BPM (Alert)
Temporal (alarm)
Date of last known Upgrade: 2021
Year Opened: 1901

The Grand Theatre is a professional theatre located at 471 Richmond St, London, Ontario. It consists of two auditoriums that run from May to September; the main auditorium has a capacity of 839. The theatre was originally built in 1901, and was reconstructed in 1978. It was then renovated in 2020, and the fire alarm system was upgraded..

System Specifications (2020-present)

FACP

The building is protected by a Mircom FX-2000 addressable fire alarm system. The panel location is unknown. The system runs Mircom's Advanced addressable protocol, and is configured for two-stage operation. The alert coding is 20BPM, and the alarm coding is temporal.

Notification Appliances

All notification appliances are System Sensor "L-Series" P4WLA horn/strobes (white, wall-mount, bilingual lettering, set to 15cd).

Initiating Devices

Pull Stations

All pull stations are Mircom MS-402AP addressable two-stage pull stations.

Automatic Detection Devices

None noticed.

Modules

There are Mircom MIX-M500MAPA addressable monitor modules supervising the sprinkler system's tamper and flow switches.
There are Mircom MIX-M500RAPA addressable relay modules serving various purposes.

There are System Sensor M500XA isolator modules on the SLC.

EOLs

There are Mircom MP-300 end of line resistor plates on all sprinkler and signal circuits.

Former System Specifications (1978-2020)

Former System Specifications
FACP: Mircom Series 1000
FACP Location: Unknown
System Type: Two-Stage Conventional
System Line Voltage: 120VAC
NAC Voltage: 24VFWR
System Coding: 20BPM (alert)
120BPM march time (alarm)
Date of last known Upgrade: 2000s
Year Installed: 1978
Year Decommissioned: 2020

FACP

The building was protected by a Mircom Series 1000 conventional fire alarm system. The panel location was unknown. The system was configured for two-stage operation. The alert signal coding was 20BPM, followed by 120BPM march time as the alarm signal.

The Series 1000 replaced an Edwards Custom 6500 in the 2000s.

Notification Appliances

All notification appliances were Edwards “Adaptabel” 333D single-stroke bells (6” gong).

Initiating Devices

Pull Stations

All pull stations were Edwards 270-GAO conventional two-stage pull stations.

Automatic Detection Devices

None noticed. The building had a sprinkler system.