System Specifications |
---|
FACP: Notifier NFS-320C FACP Location: Main Electrical Room System Type: Single-Stage Addressable System Line Voltage: 120VAC NAC Voltage: 24VDC System Coding: Temporal Strobes Synchronized: Yes, SS Date of last known Upgrade: 2023 Year Opened: 2011 |
Shoppers Drug Mart is a Canadian chain of pharmacies owned by Loblaws. This particular pharmacy is located at 1511 Walden Gate Southeast (Unit 700), in Calgary, Alberta, Canada. The pharmacy opened in 2011, and the fire alarm system was fully upgraded in 2023.
System Specifications (2023-present)
FACP
The building is protected by a Notifier NFS-320C addressable fire alarm system. The panel is located in the main electrical room. The system runs Notifier’s FlashScan addressable protocol, and the system coding is temporal.
Annunciators
There is a Notifier LCD2-80 annunciator paired with a Notifier ACM-24AT annunciator in the main entrance vestibule.
Notification Appliances
Most notification appliances are System Sensor “L-Series” P2RLA horn/strobes (red, wall-mount, bilingual lettering, set to 15cd). Areas with lower ceilings have System Sensor PC2RLA horn/strobes (red, ceiling-mount, bilingual lettering, set to 15cd).
Initiating Devices
Pull Stations
All pull stations are Notifier NBG-12LX addressable dual-action pull stations.
Automatic Detection Devices
None noticed.
Modules
There are Notifier FMM-1A addressable monitor modules supervising the sprinkler system’s tamper and flow switches.
EOLs
There are Notifier EOL-CR end-of-line resistor plates on all sprinkler and signal circuits.
System Specifications (2011-2023)
System Specifications |
---|
FACP: Simplex 4010 FACP Location: Main Electrical Room System Type: Single-Stage Addressable System Line Voltage: 120VAC NAC Voltage: 24VDC System Coding: Temporal Strobes Synchronized: Yes, SmartSync Year Decommissioned: 2023 Year Installed: 2011 |
FACP
The building was protected by a Simplex 4010 addressable fire alarm system. The panel was located in the main electrical room. The system ran Simplex’s IDNet addressable protocol, and the system coding was temporal.
Annunciators
There was a Simplex 4606-9101 annunciator in the main entrance vestibule.
Notification Appliances
Most notification appliances were Simplex “TrueAlert” 4906-9127 horn/strobes (red, wall-mount, set to 15cd). Areas with lower ceilings had Simplex 4906-9128 horn/strobes (red, ceiling-mount, set to 15cd).
Initiating Devices
Pull Stations
All pull stations were Simplex 4099-9001 addressable single-action pull stations.
Automatic Detection Devices
Not known.
Modules
There were Simplex 4090-9001 addressable monitor modules supervising the sprinkler system’s tamper and flow switches.
EOLs
There were Simplex 2081-9040C end-of-line resistor plates on all sprinkler and signal circuits.