System Specifications |
---|
FACP: Gamewell FCI E3 FACP Location: Unknown System Type: Addressable System Line Voltage: 120VAC NAC Voltage: 70VRMS (audible) 24VDC (visual) System Coding: Unknown Strobes Synchronized Yes, System Sensor Date of last known Upgrade: N/A Year Opened: 2006 |
Grand Atlantic Ocean Resort is a hotel located at 2007 S Ocean Blvd, in Myrtle Beach, South Carolina, USA. The hotel was built in 2006, and the fire alarm system is original.
System Specifications
FACP
The building is protected by a Gamewell-FCI E3 addressable fire alarm system. The panel location is unknown. The system runs Gamewell's XP95 addressable protocol, and the system tone is unknown.
Notification Appliances
All common area notification appliances are System Sensor "SpectrAlert" SP2R1224MC speaker/strobes (red, wall-mount, set to 15/75cd).
There are System Sensor "SpectrAlert" SP200W remote speakers (white, ceiling-mount) in all guest rooms..
Initiating Devices
Pull Stations
All pull stations are Gamewell MS-95-SL addressable single-action pull stations.
Automatic Detection Devices
All smoke detectors are Gamewell XP95-P addressable photoelectric smoke detectors and all heats are Gamewell XP95-T addressable heat detectors.