Toggle menu
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.

We have switched hosting. Sorry for the recent downtime. :)

40 Sunpark Plaza SE

From FireAlarmPedia
Revision as of 13:31, 26 March 2021 by Alberta Fire Alarms (talk | contribs) ("signals" is vague, you don't need to make seperate sentences for a replacement, try not to say "original from ????" all the time. Also, pull stations is fine.)

40 Sunpark Plaza SE is a mixed-use office complex located in the Sundance neighborhood of SE Calgary. The first floor contains a doctor's office, a Shoppers Drug Mart, and formerly an optometrist. It was built in 2004, and has the original fire alarm system.


System Specifications

NOTE: There were "Fire alarm repairs" in 2020, so this page may not be fully accurate. This page is accurate to July 2018.

FACP

The fire alarm panel is a Notifier AFP-200. It is original from 2004. When the system goes into alarm, the panel is set on continuous, but the notification appliances are self-coded to code 3.

Notification Appliances

The main notification appliances are the original System Sensor "SpectrAlert" P1224MC horn/strobes (red, wall-mount). There has been one replacement noted, and the replacement notification appliance a Mircom FHS-340R, which was installed in 2014 replacing the original horn/strobe.

Initiating Devices

Pull Stations

The pull stations are the original Notifier MPS-950B pull stations.

Automatic Detection Devices

There are Notifier FSP-851 addressable photoelectric smoke detectors located throughout the building, but they are not original.