System Specifications |
---|
FACP: EST QuickStart QS1 FACP Location: Main Entrance System Type: Addressable System Line Voltage: 120VAC NAC Voltage: 24VFWR System Coding: Temporal Strobes Synchronized: Yes, Self-Sync Date of last known Upgrade: N/A Year Opened: 2007 |
Walmart is a chain of big-box stores headquartered in Bentonville, Arkansas, USA. This particular store is a Supercentre, and is located at 1203 Parsons Road Northwest, in Edmonton, Alberta, Canada. The store opened in 2007, and the fire alarm system is original.
System Specifications
FACP
The building is protected by an EST QuickStart QS1 addressable fire alarm system. The panel is located in the main entrance vestibule. The system runs EST’s Signature addressable protocol, and the system coding is temporal.
Notification Appliances
The notification appliances are a mix of Edwards “Genesis” G1R-HDVM horn/strobes (red, wall-mount, set to 15cd) and Edwards G1R-VM remote strobes (red, wall-mount, set to 15cd). These devices are mounted on poles throughout the store, with two horn/strobes and remote strobes mounted opposite each other. The public washrooms have Edwards G1R-VM remote strobes (red, wall-mount, set to 15cd).
Initiating Devices
Pull Stations
All pull stations are EST SIGA-270 addressable single-action pull stations.
Automatic Detection Devices
There are EST SIGA-PS addressable photoelectric smoke detectors in the entrance vestibules, mounted on EST SIGA-SB bases. The store is equipped with a sprinkler system.
Modules
There are EST SIGA-CT1 addressable monitor modules supervising the sprinkler system’s tamper and flow switches.