Revision as of 21:41, 11 November 2024 by Alberta Fire Alarms (talk | contribs) (Created page with "{| style="float:right;border:2px solid black" |- ! System Specifications |- | |- | FACP: Edwards EST3 <br />FACP Location: Unknown <br />System Type: Single-Stage Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br />System Coding: Temporal <br>Strobes Synchronized: Yes, Genesis <br />Date of last known Upgrade: 2008 <br />Year Opened: 1980 <br /> Year Broken Up: 2017 |} '''Deerfoot Mall''' was a shopping mall located at 901 64 Ave NE, Calgary, AB...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
System Specifications
FACP: Edwards EST3
FACP Location: Unknown
System Type: Single-Stage Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VDC
System Coding: Temporal
Strobes Synchronized: Yes, Genesis
Date of last known Upgrade: 2008
Year Opened: 1980
Year Broken Up: 2017

Deerfoot Mall was a shopping mall located at 901 64 Ave NE, Calgary, AB. The mall’s anchors were Winners and Walmart at the time of closure. It opened in 1981, and was closed and broken up into three parts, which still exist as buildings D, E, F & G. The fire alarm system for the original mall was upgraded in 2008, and some parts may still exist on the systems for each building.

System Specifications (2008-2017)[edit | edit source]

Note: These specifications may not be fully accurate, as this system no longer exists. This page is accurate to 2017 prior to being broken up.

FACP[edit | edit source]

The building was protected by an Edwards EST3 addressable fire alarm system. The panel location was unknown. The system ran Edwards’ Signature addressable protocol, and the system coding was temporal.

Annunciators[edit | edit source]

There was an Edwards EST3-LCDANN annunciator in one of the entrance vestibules.

Notification Appliances[edit | edit source]

All notification appliances were Edwards “Genesis” GC-HDVM horn/strobes (white, ceiling-mount, no marking, set to 30cd).

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

All pull stations were EST SIGA-270 addressable single-action pull stations.

Automatic Detection Devices[edit | edit source]

There were EST SIGA-PS addressable photoelectric smoke detectors in some parts, mounted on EST SIGA-SB bases.

Modules[edit | edit source]

There were EST SIGA-CT1 addressable monitor modules supervising the sprinkler system’s tamper and flow switches.
There were EST SIGA-CR addressable relay modules serving various purposes.

EOLs[edit | edit source]

There were Edwards EOL-P1 end-of-line resistor plates on all sprinkler and signal circuits.