Revision as of 13:05, 12 January 2025 by Alberta Fire Alarms (talk | contribs) (Created page with "{| style="float:right;border:2px solid black" |- ! System Specifications |- | |- | FACP: Notifier NFS2-3030C <br />FACP Location: Main Entrance <br />System Type: Single-Stage Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br />System Coding: Temporal <br>Strobes Synchronized: Yes, System Sensor <br />Date of last known Upgrade: N/A <br />Year Opened: 2017 |} '''Holiday Inn''' is a chain of budget hotels owned by IHG. This particular hotel is lo...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
System Specifications
FACP: Notifier NFS2-3030C
FACP Location: Main Entrance
System Type: Single-Stage Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VDC
System Coding: Temporal
Strobes Synchronized: Yes, System Sensor
Date of last known Upgrade: N/A
Year Opened: 2017

Holiday Inn is a chain of budget hotels owned by IHG. This particular hotel is located at 8360 Blackfoot Trail SE, Calgary, AB. The hotel opened its doors in 2017, and the fire alarm system is original.

System Specifications

FACP

The hotel is protected by a Notifier NFS2-3030C addressable fire alarm system. The panel is located at the main entrance. The system runs Notifier’s FlashScan addressable protocol, and the system coding is temporal.

Annunciators

There is a Notifier LCD-160 LCD annunciator located next to the front desk.

Notification Appliances

All original notification appliances are from System Sensor’s “SpectrAlert Advance” line of products.
The hallways, lobby and guest rooms have System Sensor P2RA horn/strobes (red, wall-mount).
The pool area has System Sensor P2RKA weatherproof horn/strobes (red, wall-mount), as well as System Sensor SRKA weatherproof remote strobes (red, wall-mount).
There is one System Sensor “L-Series” P2RLA horn/strobes (red, wall-mount), located in the lounge.

Initiating Devices

Pull Stations

All pull stations are Notifier N-MPS-SA addressable single-action pull stations.

Automatic Detection Devices

There are Notifier FSP-851A addressable photoelectric smoke detectors throughout the hotel, mounted on System Sensor B210LPA bases.

Modules

There are Notifier FMM-1A addressable monitor modules supervising the sprinkler system's tamper and flow switches.
There are Notifier FRM-1A addressable relay modules serving various purposes.
There are Notifier ISO-XA isolator modules on each SLC.

EOLs

There are Notifier EOL-CR end-of-line resistor plates on all sprinkler and signal circuits.