Revision as of 20:07, 28 April 2025 by Alberta Fire Alarms (talk | contribs) (Created page with "{| style="float:right;border:2px solid black" |- ! System Specifications |- | |- | FACP: Mircom FX-2000 <br />FACP Location: Main Entrance Vestibule <br />System Type: Single-Stage Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: Temporal <br>Strobes Synchronized: No <br />Date of last known Upgrade: 2025 <br />Year Opened: 2006 |} '''The Mission Gate''' is an apartment building located at 509 21 Ave SW, Calgary, Alberta, Cana...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
System Specifications
FACP: Mircom FX-2000
FACP Location: Main Entrance Vestibule
System Type: Single-Stage Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VFWR
System Coding: Temporal
Strobes Synchronized: No
Date of last known Upgrade: 2025
Year Opened: 2006

The Mission Gate is an apartment building located at 509 21 Ave SW, Calgary, Alberta, Canada. The building was completed in 2006, and the fire alarm system is original.

System Specifications (2006-present)

FACP

The building is protected by a Mircom FX-2000 addressable fire alarm system. The panel is located in the main entrance vestibule. The system runs Mircom's CLIP addressable protocol, and the system coding is temporal.

Notification Appliances

All common area notification appliances are Mircom "Select-a-Horn/Strobe" FHS-240R horn/strobes (red, wall-mount, 15cd).
Each suite has a Mircom MH-S25WA silenceable mini-horn (white).

Initiating Devices

Pull Stations

All pull stations are Mircom MS-401AD addressable single-action pull stations.

Automatic Detection Devices

Most smoke detectors are Mircom MIX-1251BA addressable ionization smoke detectors, throughout the building.
Some areas have Mircom MIX-2351APA addressable photoelectric smoke detectors as deficiency replacements.
There is a Mircom MIX-DH200PLA addressable photoelectric smoke detector on the main air handling unit.

Modules

There are Mircom MIX-M500MA addressable monitor modules supervising the sprinkler system's tamper and flow switches.
There are Mircom MIX-M500RA addressable relay modules serving various purposes.
There are System Sensor M500XA isolator modules on the SLC.

EOLs

There are Mircom MP-300 end-of-line resistor plates on all sprinkler and class-B signal circuits.