Revision as of 22:09, 18 December 2025 by Alberta Fire Alarms (talk | contribs) (Created page with "{| style="float:right;border:2px solid black" |- ! System Specifications |- | |- | FACP: EST QuickStart QS4<br />FACP Location: Main Floor Office/Server Room<br />System Type: Single-Stage Addressable<br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR<br />System Coding: Temporal<br>Strobes Synchronized: Yes, Genesis<br />System Installed: 2025<br />Most Recent Known Modification: Duct Smoke<br />Year Opened: 1959 |} NOTE: This is an hobby system, and is not an...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
System Specifications
FACP: EST QuickStart QS4
FACP Location: Main Floor Office/Server Room
System Type: Single-Stage Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VFWR
System Coding: Temporal
Strobes Synchronized: Yes, Genesis
System Installed: 2025
Most Recent Known Modification: Duct Smoke
Year Opened: 1959

NOTE: This is an hobby system, and is not an official fire alarm system. This system is installed in a private residence, therefore it does not need to meet CAN-ULC codes.

The Mayland House is a private residence located in Northeast Calgary, Alberta, Canada. The house was built in 1959, and the fire alarm system was installed in 2025.

System Specifications

FACP

The house is protected by an EST QuickStart QS4 addressable fire alarm system. The panel is located in the main floor office/server room. The system runs EST's Signature addressable protocol, and the system coding is temporal.

Notification Appliances

All notification appliances are EST "Genesis" G1R-HOV15 horn/strobes (red, wall-mount, no marking, 15cd).

Initiating Devices

Pull Stations

All pull stations are EST SIGA-270 addressable single-action pull stations.

Automatic Detection Devices

There are EST SIGA-PS addressable photoelectric smoke detectors in all bedrooms, the office, and all corridors and common areas.
There are EST SIGA-HRS addressable 135°F fixed-temperature/rate-of-rise heat detectors in the washroom and kitchen.
All aforementioned detectors are mounted on EST SIGA-SB bases.
There is an EST "SuperDuct" SIGA-SD addressable photoelectric duct smoke detector on the furnace duct.

Modules

There is an EST SIGA-CR addressable relay module for furnace shutdown.
There is an EST "Genesis SignalMaster" G1M-RM signal control module installed on NACs 1 and 2 for 4-wire operation and strobe synchronization.

EOLs

None currently present.