Dover Community Association

From FireAlarmPedia
Revision as of 16:32, 3 May 2026 by TwentyThree33 (talk | contribs) (Created page with "{| style="float:right;border:2px solid black" |- ! System Specifications |- | |- | FACP: Mircom FA-1000<br />FACP Location: Main Entrance<br />System Type: Single-Stage Conventional<br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR<br />System Coding: Temporal<br>Strobes Synchronized: N/A<br />Date of last known Upgrade: 1992<br />Most Recent Known Modification: N/A<br />Year Opened: 1977 |} The '''Dover Community Association''' is a community centre located at...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
System Specifications
FACP: Mircom FA-1000
FACP Location: Main Entrance
System Type: Single-Stage Conventional
System Line Voltage: 120VAC
NAC Voltage: 24VFWR
System Coding: Temporal
Strobes Synchronized: N/A
Date of last known Upgrade: 1992
Most Recent Known Modification: N/A
Year Opened: 1977

The Dover Community Association is a community centre located at 3133 30 Ave SE, in Calgary, Alberta, Canada. The building was built in 1977, and the fire alarm system was upgraded in 1992.

System Specifications (1992-present)

FACP

The building is protected by a Mircom FA-1000 conventional fire alarm system. The panel is located at the main entrance. The system coding is likely temporal.

Notification Appliances

Most notification appliances are Edwards 439D-6AWC vibrating bells (6" gong).
Some areas have Edwards 439D-10AWC vibrating bells (10" gong).

Initiating Devices

Pull Stations

All pull stations are Edwards 270-SPO conventional single-action pull stations.

Automatic Detection Devices

There are System Sensor 5601A conventional 135°F fixed-temperature/rate-of-rise heat detectors in all bar and storage areas.
There are FDD CF-200 conventional 200°F fixed-temperature heat detectors in the furnace and janitor rooms.
There is a System Sensor C2W-BA conventional photoelectric smoke detector at the top of the elevator shaft.

EOLs

There are Edwards EOL-P1 end of line resistor plates on all circuits.