Model Number
|
Images
|
Quantity
|
Type
|
Manufacturing Date
|
Notes
|
Origin
|
Simplex 2099-9901
|
|
2
|
Single-stage, SPST, single-action Conventional Pull Station
|
1988
|
The button on one is from a Mirtone 73303.
|
R.T. Alderman School
|
Simplex 4099-9004
|
|
1
|
IDNet Addressable single-stage, single-action pull station
|
2018
|
Missing its lock.
|
Canadian Alarms
|
Simplex 4099-9004CB
|
|
2
|
IDNet Addressable single-stage, single-action bilingual pull station
|
2017
|
Fairly rare.
|
CJ9899
|
Simplex 4251-30
|
|
1
|
Single-stage, SPST, break-glass dual-action conventional pull station
|
1979
|
Owned by Simplex NimrodES, but was loaned to me with permission.
|
Kijiji
|
Edwards 270-SPO
|
|
4
|
Single-stage, SPST, single-action conventional pull station
|
1960s, 1980s, 1990s, 2000
|
1960s one is surprisingly hard to pull! 1980s one does not work.
|
El Chupacabra, Canadian Alarms, other friend
|
Edwards 270-SPOF
|
|
1
|
Single-stage, SPST, single-action conventional pull station
|
1980s
|
French lettering
|
El Chupacabra
|
Edwards 270A-SPO
|
|
1
|
Single-stage, SPST, single-action conventional pull station
|
1994
|
American model, in remarkably good condition.
|
El Chupacabra
|
Edwards 270-GAO-DOC
|
|
2
|
Dual-stage, DPST, single-action conventional pull station
|
1997, 2003
|
Very rare but cool pull stations. Both have the security screw.
|
CJ9899
|
EST SIGA-270P
|
|
1
|
Addressable dual-stage, single-action pull station
|
2016
|
Soon to be owned by Twentytwo22
|
Phuntington
|
Siemens MS-53C
|
|
2
|
Dual-stage, DPST single-action conventional pull station
|
2014
|
Very good pull stations overall, but why are terminals 1 and 4 for the button, and 2 and 3 for the keyswitch?
|
CJ9899
|
Pyrotronics MS-51B
|
|
1
|
Single-stage, SPST single-action conventional pull station
|
1980s
|
One of my personal favourites! Very rare too.
|
El Chupacabra
|
Mirtone 73303
|
|
4
|
Single-stage, SPST single-action conventional pull station
|
1986, 1988, 1992
|
The reset difficulty is significantly over-exaggerated. It's really not that hard.
|
El Chupacabra, Canadian Alarms
|
Mirtone 73353
|
|
1
|
Single-stage, SPST single-action conventional pull station
|
1997
|
I'm the only known enthusiast to have this alarm.
|
Phuntington
|
Notifier MPS-950B
|
|
2
|
Single-stage, SPST single-action conventional pull station
|
2001
|
Metal bar that holds the handle in place is loose on both. Frequent adjustment is required.
|
Phuntington
|
Fire-Lite BG-12L
|
|
1
|
Single-stage, SPST dual-action conventional pull station
|
2014
|
Will be traded to Simplex NimrodES in exchange for his BG-12.
|
Twentytwo22
|
Edwards 275-C111
|
|
1
|
Single-stage, SPST single-action conventional pull station
|
1992
|
Very, very nice pull station. I'd highly recommend purchasing one.
|
Canadian Alarms
|
Edwards 274-111
|
|
1
|
Single-stage, SPST single-action conventional pull station
|
1970s
|
Not a very well-made device. The 275-C111 is much better.
|
7044 Ogden Road SE
|
Mircom MS-401AD
|
|
1
|
Addressable single-stage, single-action pull station
|
2008
|
|
Phuntington
|
Mircom MS-401
|
|
1
|
Single-stage, SPST single-action conventional pull station
|
2014
|
Basic but nice pull station. The edges are really sharp on this one. I actually cut myself pulling it once.
|
Canadian Alarms
|
Notifier MPS-950KB20C
|
|
1
|
Dual-stage, DPST single-action conventional pull station
|
2013?
|
Weird pull station overall, but in very good condition.
|
CJ9899
|
Honeywell FM-950K
|
|
2
|
Dual-stage, SPST single-action conventional pull station
|
1980s
|
One will be going to Simplex NimrodES as part of a grad present.
|
CJ9899
|
FCI MS-2E
|
|
1
|
Single-stage, SPST dual-action conventional pull station
|
2000s
|
Labeled "EPO and Disconnect", has an issue with the pulling mechanism.
|
eBay
|
Simplex 2099-9754
|
|
1
|
Single-stage, SPST single-action conventional pull station
|
2010
|
One of my favorites.
|
eBay
|
Notifier NOT-BG12LX
|
|
1
|
Addressable single-stage dual-action pull station
|
2011
|
Works with the FireWarden (NFW) panels only.
|
Phuntington
|
Notifier NBG-12LX
|
|
1
|
Addressable single-stage dual-action pull station
|
2019
|
Works with the AFP and Onyx-series panels. Runs on both FlashScan and CLIP. Acquired new due to it "not working", despite working fine.
|
Phuntington
|
Notifier N-MPS-SA
|
|
1
|
Addressable single-stage dual-action pull station
|
2020
|
Was acquired new as a birthday present from Steve Huska, regional manager at Viking Fire Protection.
|
Viking Fire Protection
|
Notifier LNG-1R
|
|
6
|
Single-stage, SPST dual-action conventional pull station
|
December 1998
|
Very rare pull stations! Very good devices, but quite fragile.
|
Nick Olvera
|