More actions
System Specifications |
---|
FACP: Simplex 4007ES System Type: Hybrid System Line Voltage: 120VAC NAC Voltage: 24VDC Date of last known Upgrade: 2021 Year Opened: 1996 |
Safeway is a chain of grocery stores in Alberta. This particular location is in Dalhousie, NW Calgary. It is officially called Safeway Dalhousie Station, due to being adjacent to the Dalhousie station on the CTrain line. It was built in 1996, and the fire alarm system was recently replaced, and only a few pull stations remain. The store is in a large plaza, however only the Safeway is protected by a fire alarm system.
System Specifications
FACP
The fire alarm panel is a Simplex 4007ES, specifically 4007-9202 (Platinum cabinet). It is located in the entrance on the right. It replaced the original EST 6632 in 2021 because Safeway likes Simplex, and because the 6632 was large, there is drywall covering the 6632's space. The permit issued for this upgrade was "Fire Alarm System Modification - Replace Fire Alarm Panel and select initiating/signaling devices." on February 12, 2021.
Notification Appliances
The notification appliances are all from Simplex's "TrueAlert" lineup. The store has Simplex 4906-9127 (red, wall-mount, SmartSync) horn/strobes installed in the original bell/strobes places, leaving the area not covered by the horn/strobe unpainted. On the ceilings, there are Simplex 4906-9104 (white, ceiling-mount, SmartSync) remote strobes, installed in place of the previous strobes. Outside the entrance, there is a Simplex 4906-9131 (red, wall-mount, SmartSync) weatherproof remote strobe.
Initiating Devices
Pull Stations
The pull stations are still mostly the original Edwards 270-SPO pull stations, but there is one Simplex 2099-9754 at the entrance, installed during the upgrade.
Automatic Detection Devices
None noticed.
Former System Specifications
System Specifications |
---|
FACP: EST 6632 System Type: Conventional System Line Voltage: 120VAC NAC Voltage: 24VFWR Date of last known Upgrade: Early 2010s Year Decommissioned: 2021 |
FACP
The fire alarm control panel was an EST 6632. It was original and was located in the entrance on the right. In 2021, it was replaced with a Simplex 4007ES.
Notification Appliances
The notification appliances mainly consisted of the original Edwards 439D-10AWC vibrating bells on EST "Integrity" 403-5A-R strobe plates. In the floral section, there was an Edwards 439D-10AWC bell on a Wheelock RSSP-24MCW strobe plate, the Wheelock strobe plate replaced an EST strobe plate that stopped working. On the ceiling, there was a mix of EST "Integrity" 202-5A-T (red) and 202-5A-TW (white) remote strobes scattered around, all with the standard wall "FIRE" lenses. They were original, and they are for additional visual coverage. Some of them had been replaced with System Sensor "SpectrAlert Advance" SRA (red, wall) remote strobes, again on the ceiling. For outdoor notification, the there was an Edwards 439D-10AWC vibrating bell on an EST 403-5A-R strobe plate at the entrance.
Initiating Devices
Pull Stations
The pull stations were all the original Edwards 270-SPO. Some are still installed.
Automatic Detection Devices
None noticed.