ThePurpleMage's House

From FireAlarmPedia

ThePurpleMage’s house is a split level house in the community of Lake Bonavista.

The house was built in 1973

System Specifications

FACP

The house is protected by an EST IO-1000 Addressable fire alarm control panel. The panel is located in the basement furnace/boiler room. The panel replaced an Edwards 2280 in December of 2021

When in alarm the system does Temporal code/code 3.

Notification Appliances

The Notification Appliances consist of a mix of Edwards 439D-6AWC (6 inch) vibrating bells and Simplex 2901-9723 (6 inch) motor bells

Initiating Devices

Pull Stations

The manual pull stations consist of Notifier MPS-950B (Bilingual) conventional single action pull stations. And Notifier LNG-1R (Red) dual action conventional pull stations. These pull stations are wired into EST SIGA CT-1 monitor modules

Automatic Detection Devices

The Automatic Detection Devices consist of EST SIGA PCD addressable smoke detectors.