5578 Signal Hill Drive SW, Calgary

From FireAlarmPedia
Revision as of 23:14, 13 January 2023 by TwentyThree33 (talk | contribs) (Why do they feel the need to have different NAs for every unit?)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
System Specifications
FACP: Notifier AFP-200
FACP Location: Rear Sprinkler Room
System Type: Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VDC
System Coding: Temporal
Strobes Synchronized: No
Date of last known Upgrade: 2020
Year Opened: 1998

5578 Signal Hill Drive SW is the address of a midsized shopping plaza located in Signal Hill Centre, Calgary, Alberta, Canada. The plaza contains Wine & Beyond, Dollarama, Winners, Chatters, and numerous vacant units. The plaza opened in 1998, and the fire alarm system is original.

System Specifications

FACP

The building is protected by a Notifier AFP-400 addressable fire alarm system. The panel is located in the main sprinkler room at the rear of the building. The system runs Notifier’s CLIP addressable protocol, and the system coding is likely temporal.

Annunciators

There are two Notifier LCD-80 annunciators on the system: one in the Staples entrance vestibule, and one outside the building.

Notification Appliances

Dollarama

The notification appliances are a mix of System Sensor P2RLA horn/strobes (red, wall-mount, set to 15cd) and System Sensor PC2RLA horn/strobes (red, ceiling-mount, set to 15cd). These were installed in 2020 when it opened.

Winners

All notification appliances are Wheelock MB-G10-24 motor bells (10” gong) mounted on Wheelock RSSP-2415W strobe plates (15cd).

Staples

All notification appliances but one are Wheelock MB-G6-24 motor bells (6” gong) mounted on Wheelock RSSP-24MCW strobe plates (set to 15cd). There is one Notifier KMS-6-24A motor bell (6” gong) mounted on the original strobe plate as a deficiency replacement.

Initiating Devices

Pull Stations

All pull stations are Notifier NFM-950B conventional single-action pull stations, mostly mounted on Notifier MPS-DBB back boxes. All stations are wired to Notifier MMX-101A addressable monitor modules, mounted directly behind each station.

Automatic Detection Devices

None noticed.