Toggle menu
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.

We have switched hosting. Sorry for the recent downtime. :)

Red Roof Inn Dallas-DFW Airport North

From FireAlarmPedia
Revision as of 21:54, 23 July 2023 by TwentyThree33 (talk | contribs) (Red Roof)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
System Specifications
FACP: Gamewell ZANS-400
FACP Location: Behind Front Desk
System Type: Conventional
System Line Voltage: 120VAC
NAC Voltage: 24VDC
System Coding: Continuous?
Strobes Synchronized: No
Date of last known Upgrade: 2000s
/>Year Opened: 1985

Red Roof Inn is an American chain of budget hotels and motels. This particular hotel is located at 8150 Esters Boulevard, in Irving, Texas, USA. The hotel opened in 1985, and the fire alarm system is partially original.

System Specifications

FACP

The building is protected by a Gamewell ZANS-400 conventional fire alarm system. The panel is located behind the front desk. The system coding is likely continuous.

Notification Appliances

There are Wheelock AS-241575W-FR horn/strobes (red, wall-mount, 15/75cd) throughout the hotel’s common areas. There are no notification appliances in the guest rooms.

Initiating Devices

Pull Stations

Most pull stations are Gamewell M46-29 conventional single-action pull stations. There are Fire-Lite BG-12LO {| style="float:right;border:2px solid black" |- ! System Specifications |- | |- | FACP: Gamewell ZANS-400
FACP Location: Behind Front Desk
System Type: Conventional
System Line Voltage: 120VAC
NAC Voltage: 24VDC
System Coding: Continuous?
Strobes Synchronized: No
Date of last known Upgrade: 2000s
/>Year Opened: 1985 |}

‘’’Red Roof Inn’’’ is an American chain of budget hotels and motels. This particular hotel is located at 8150 Esters Boulevard, in Irving, Texas, USA. The hotel opened in 1985, and the fire alarm system is partially original.

System Specifications

FACP

The building is protected by a Gamewell ZANS-400 conventional fire alarm system. The panel is located behind the front desk. The system coding is likely continuous.

Notification Appliances

There are Wheelock AS-241575W-FR horn/strobes (red, wall-mount, 15/75cd) throughout the hotel’s common areas. There are no notification appliances in the guest rooms.

Initiating Devices

Pull Stations

Most pull stations are Gamewell M46-29 conventional single-action pull stations. There are Fire-Lite BG-12LO weatherproof conventional single-action pull stations in the hotel’s outdoor corridors.

Automatic Detection Devices

There are System Sensor 2W-B conventional photoelectric smoke detectors throughout the hotel. weatherproof conventional single-action pull stations in the hotel’s outdoor corridors.

Automatic Detection Devices

There are System Sensor 2W-B conventional photoelectric smoke detectors throughout the hotel.