System Specifications
FACP: Notifier NFS-320C
FACP Location: Electrical Room
System Type: Hybrid-Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VDC
System Coding: Temporal
Strobes Synchronized: No
Date of last known Upgrade: 2020s
Year Opened: 1970s

Wishart Elementary School is an elementary school located at 3310 Wishart Road, in Colwood, British Columbia, Canada. The school opened in the 1970s, and was renovated in the 1990s. The fire alarm system is not original.

System Specifications (Main Building, 2020-present)

FACP

The building is protected by a Notifier NFS-320C hybrid-addressable fire alarm system. The panel is located in the main electrical room. The system runs Notifier’s FlashScan addressable protocol, and the system coding is temporal.

Notification Appliances

Most notification appliances are Simplex 2901-9722 motor bells (10” gong). Some areas have Notifier KMS-10-24A motor bells (10” gong) as deficiency replacements. There is an Edwards 439D-6AWC vibrating bell (6” gong) mounted on an Edwards 403-5A-R strobe plate (15cd) by the main office.

Initiating Devices

Pull Stations

Most pull stations are Notifier NBG-12L conventional dual-action pull stations. Some areas have FCI-rebranded N-MPS-SC conventional single-action pull stations.

Automatic Detection Devices

There are Simplex 2098-9508 conventional ionization smoke detectors throughout the building. Some areas have System Sensor “i3” C2W-BA conventional photoelectric smoke detectors as deficiency replacements. The electrical rooms have Simplex 4098-9703 conventional duct detectors with 4098-9701 photoelectric smoke detector heads.

System Specifications (Portables)

FACP

The portables are protected by the same panel as the main building, however the system is wired as addressable. The system coding is temporal.

Notification Appliances

All notification appliances are System Sensor “L-Series” P2RLA horn/strobes (red, wall-mount, bilingual lettering, set to 15cd).

Initiating Devices

Pull Stations

All pull stations are Notifier NBG-12LX addressable dual-action pull stations.

Automatic Detection Devices

There are Notifier FSP-851A addressable photoelectric smoke detectors throughout the portables, mounted on System Sensor B210LPA bases. There are also FDD CR-135 conventional 135 Fixed/Rate-of-Rise heat detectors throughout the portables.