System Specifications
FACP: Gamewell-FCI E3
FACP Location: Unknown
System Type: Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VDC
System Coding: Continuous
Strobes Synchronized: No
Date of last known Upgrade: 2023
Year Opened: 1994

North Clackamas Aquatic Park is a waterpark located at 7300 Southeast Harmony Road, in Milwaukie, Oregon, USA. The park opened in 1994, and the fire alarm system was upgraded in 2023.

System Specifications (2023-present)

FACP

The building is protected by a Gamewell-FCI E3 addressable fire alarm system. The panel location is unknown. The system runs Gamewell’s Velocity addressable protocol, and the system coding is likely continuous.

Notification Appliances

Most notification appliances are Simplex 2901-9845 remote horns (red, wall-mount) mounted on Simplex 4904-9105 strobe plates (15cd). Areas requiring additional visual coverage have Simplex 4904-9137 remote strobes (15cd) and Wheelock LSM-24 remote strobes (15cd). Wheelock AS-24MCW-FR horn/strobes (red, wall-mount, set to 15cd) and Wheelock “Exceder” HSR horn/strobes (red, wall-mount, set to 15cd) are installed as deficiency replacements throughout.

Initiating Devices

Pull Stations

All pull stations are Gamewell-FCI MS-7ASF addressable single-action pull stations.

Automatic Detection Devices

Not known.

System Specifications (1994-2023)

FACP

The building was protected by a Simplex 4002 conventional fire alarm system. The panel location was unknown. The system coding was continuous.

Notification Appliances

Most notification appliances were Simplex 2901-9845 remote horns (red, wall-mount) mounted on Simplex 4904-9105 strobe plates (15cd). Areas requiring additional visual coverage had Simplex 4904-9137 remote strobes (15cd) and Wheelock LSM-24 remote strobes (15cd). Wheelock AS-24MCW-FR horn/strobes (red, wall-mount, set to 15cd) and Wheelock “Exceder” HSR horn/strobes (red, wall-mount, set to 15cd) were installed as deficiency replacements throughout. All notification appliances are still in use on the new system.

Initiating Devices

Pull Stations

All pull stations were Simplex 2099-9754 conventional single-action pull stations.

Automatic Detection Devices

There were Simplex 2098-9201 conventional photoelectric smoke detectors throughout the building. Some areas had Simplex “TrueAlarm” 4098-9601 conventional photoelectric smoke detectors as deficiency replacements.