Toggle menu
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.

We have switched hosting. Sorry for the recent downtime. :)

Peace Hills Trust Tower

From FireAlarmPedia
Revision as of 13:58, 22 June 2024 by TwentyThree33 (talk | contribs) (Created page with "{| style="float:right;border:2px solid black" |- ! System Specifications |- | |- | FACP: Notifier NFS2-3030C <br />FACP Location: Unknown <br />System Type: Addressable <br /...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
System Specifications
FACP: Notifier NFS2-3030C
FACP Location: Unknown
System Type: Addressable
System Line Voltage: 120VAC
NAC Voltage: 70.7VRMS (Audible)
24VDC (Visual)
System Coding: Unknown
Strobes Synchronized: Yes, SS
Date of last known Upgrade: 2012
Year Opened: 1982

Peace Hills Trust Tower is an office building located at 10011 109 Street NW, in Downtown Edmonton, Alberta, Canada. The building was built in 1982, and the fire alarm system was upgraded in 2012.

System Specifications (2012-present)

Please note that some system details are unconfirmed. This page should not be used for official purposes.

FACP

The building is protected by a Notifier NFS2-3030C addressable fire alarm system. The panel location is unknown. The system runs Notifier’s FlashScan addressable protocol, and is equipped with voice evacuation. The system is configured for two-stage operation, however the messages and/or tones are unknown at this time.

Annunciators

There is a Notifier ACM-24AT annunciator in the main entrance vestibule.

Notification Appliances

All known notification appliances are System Sensor “SpectrAlert Advance” SPSWA speaker/strobes (white, wall-mount, set to 70V/15cd).

Initiating Devices

Pull Stations

All pull stations are Notifier N-MPS-2A addressable two-stage single-action pull stations.

Automatic Detection Devices

There are Notifier FSP-851A addressable photoelectric smoke detectors in some areas, mounted on System Sensor B710LPA bases.

Modules

There are Notifier FMM-1A addressable monitor modules supervising the generator, and the sprinkler system’s tamper and flow switches.
There are Notifier FRM-1A addressable relay modules serving various purposes.

EOLs

There are Notifier EOL-CR end of line resistor plates on all signal and sprinkler circuits.