Maple Ridge School

From FireAlarmPedia
System Specifications
FACP: Simplex 4010
FACP Location: Unknown
System Type: Single-Stage Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VDC
System Coding: Temporal
Strobes Synchronized: Yes, Wheelock
Date of last known Upgrade: 2015
Year Opened: 1976

Maple Ridge School is an elementary school located at 10203 Maplemont Rd SE, Calgary, Alberta. The school has a capacity of approximately 600 students, and was built in 1967. The school received its most recent fire alarm upgrade in 2015.

System Specifications (2015-present)[edit | edit source]

FACP[edit | edit source]

The building is protected by a Simplex 4010 addressable fire alarm system. The panel location is unknown. The system runs Simplex's IDNet addressable protocol, and the system coding is temporal.

Notification Appliances[edit | edit source]

All notification appliances are Wheelock MT-12/24R remote horns (red, wall-mount) on Wheelock RSSP-24MCW strobe plates. The horns are set to horn, and the strobes are set to 15cd.

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

All pull stations are Simplex 4099-9001 addressable single-action pull stations.

Automatic Detection Devices[edit | edit source]

There are Simplex "TrueAlarm" 4098-9714 addressable photoelectric smoke detectors located throughout the facility, mounted on Simplex 4098-9792 addressable bases.

EOLs[edit | edit source]

There are Simplex 2081-9040C end of line resistor plates on all signal circuits.

System Specifications (previous system, late 1980s-2015)[edit | edit source]

System Specifications
FACP: Simplex 4002
FACP Location: Unknown
System Type: Conventional
System Line Voltage: 120VAC
NAC Voltage: 24VDC
System Coding: Continuous
Strobes Synchronized: No
Date of last known Upgrade: N/A
Year Decomissioned: 2015

NOTE: This system is unconfirmed, as it is based off ThePurpleMage's memory, and the system at the neighboring R.T. Alderman School.

FACP[edit | edit source]

The building was likely protected by a Simplex 4002 conventional fire alarm system. The system coding was likely continuous.

Notification Appliances[edit | edit source]

The notification appliances were Simplex 2901-9833 mechanical horns (red) on Simplex 2903-9101 strobe plates.

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

The pull stations were likely Simplex 2099-9901 conventional pull stations.

Automatic Detection Devices[edit | edit source]

There were Simplex 2098-9110 ionization smoke detectors throughout the school.

EOLs[edit | edit source]

There were Simplex 2081-9040C end of line resistor plates on all circuits.