System Specifications |
---|
FACP: EST iO500 FACP Location: Main Entrance Vestibule System Type: Single-Stage Addressable System Line Voltage: 120VAC NAC Voltage:24VFWR System Coding: Temporal Strobes Synchronized: Yes, Genesis Date of last known Upgrade: N/A Year Opened: 2012 |
Grand Professional Building is a 2-story multi-use retail and medical building located at 100 Grande Blvd, in Cochrane, Alberta, Canada. The building was built in 2012, and the fire alarm system is original.
System Specifications[edit | edit source]
FACP[edit | edit source]
The building is protected by an EST iO500 addressable fire alarm system. The panel is located in the main entrance vestibule. The system runs EST's Signature addressable protocol, and the system coding is temporal.
Notification Appliances[edit | edit source]
All notification appliances are Edwards "Genesis" G1R-HDVM horn/strobes (red, wall-mount, no marking, set to 15cd).
Initiating Devices[edit | edit source]
Pull Stations[edit | edit source]
All pull stations are EST SIGA-270 addressable single-action pull stations.
Automatic Detection Devices[edit | edit source]
There are EST SIGA-PS addressable photoelectric smoke detectors at the top of each stairwell, mounted on EST SIGA-SB bases.
Modules[edit | edit source]
There are EST SIGA-CT1 addressable monitor modules supervising the sprinkler system's tamper and flow switches.
EOLs[edit | edit source]
There are Edwards EOL-P1 end of line resistor plates on all sprinkler and signal circuits.