FACP: Mircom FX-2000 FACP Location: Unknown System Type: Single-Stage Addressable System Line Voltage: 120VAC NAC Voltage: 24VFWR System Coding: Temporal Strobes Synchronized: No Date of last known Upgrade: 2010s Year Opened: 2008 |
Co-op Food Store is a chain of co-operative grocery stores. This particular store is located at 2512 14 Ave, in Wainwright, Alberta, Canada. The store was built in 2008, and the fire alarm system was partially upgraded in the 2010s.
System Specifications (2010s-present)[edit | edit source]
FACP[edit | edit source]
The building is protected by a Mircom FX-2000 addressable fire alarm system. The panel location is unknown. The system runs Mircom’s CLIP addressable protocol, and the system coding is temporal.
Annunciators[edit | edit source]
There is a Mircom RAX-LCD annunciator paired with a Mircom RAX-1048TZDS annunciator in the main entrance vestibule, mounted in a Mircom BB-1002 enclosure.
Notification Appliances[edit | edit source]
All notification appliances are Edwards “Genesis” G1-HDVM horn/strobes (white, wall-mount, no marking, set to 15cd) mounted on Edwards G1T trim plates.
Initiating Devices[edit | edit source]
Pull Stations[edit | edit source]
All pull stations are Mircom MS-401AD addressable single-action pull stations.
Automatic Detection Devices[edit | edit source]
None noticed.
Modules[edit | edit source]
There are Mircom MIX-M500MAPA addressable monitor modules supervising the sprinkler system’s tamper and flow switches.
EOLs[edit | edit source]
There are Edwards EOL-P1 end of line resistor plates on all sprinkler and signal circuits.
Former System Specifications (2008-2010s)[edit | edit source]
Please note that the below specifications are purely speculated by site staff, and should not be used for official purposes.
Former System Specifications |
---|
FACP: EST QuickStart QS1 FACP Location: Unknown System Type: Single-Stage Addressable System Line Voltage: 120VAC NAC Voltage: 24VFWR System Coding: Temporal Strobes Synchronized: Yes, per-NAC Date of last known Upgrade: N/A Year Installed: 2008 Year Decommissioned: 2010s |
FACP[edit | edit source]
The building was protected by an EST QuickStart QS1 addressable fire alarm system. The panel location was unknown. The system ran EST’s Signature addressable protocol, and the system coding was temporal.
Annunciators[edit | edit source]
There was an EST QSA-1-S annunciator in the main entrance vestibule.
Notification Appliances[edit | edit source]
All notification appliances were Edwards “Genesis” G1-HDVM horn/strobes (white, wall-mount, no marking, set to 15cd) mounted on Edwards G1T trim plates.
These were not replaced during the upgrade, and are still in use.
Initiating Devices[edit | edit source]
Pull Stations[edit | edit source]
All pull stations were EST SIGA-270 addressable single-action pull stations.
Automatic Detection Devices[edit | edit source]
Not known.
Modules[edit | edit source]
There were EST SIGA-CT1 addressable monitor modules supervising the sprinkler system’s tamper and flow switches.
EOLs[edit | edit source]
There were Edwards EOL-P1 end of line resistor plates on all sprinkler and signal circuits.
These were not replaced during the upgrade, and are still in use.