More actions
System Specifications |
---|
FACP: Vigilant VM-1 FACP Location: Unknown System Type: Addressable System Line Voltage: 120VAC NAC Voltage: 70.7VRMS (Audible) 24VDC (Visual) System Coding: Unknown Strobes Synchronized: Yes, Genesis Date of last known Upgrade: N/A Year Opened: 2018 |
Hilton Garden Inn is a chain of midrange hotels owned by Hilton. The chain is headquartered in McLean, Virginia, USA, and has locations globally. This particular hotel is located at 401 S San Fernando Boulevard, in Burbank, California, USA. The hotel opened in 2018, and the fire alarm system is original.
System Specifications[edit | edit source]
FACP[edit | edit source]
The building is protected by a Vigilant VM-1 addressable fire alarm system. The panel location is unknown. The system runs Vigilant’s GSA addressable protocol, and is equipped with voice evacuation. The messages and/or tones are unknown at this time.
Annunciators[edit | edit source]
There is a Vigilant K-RLCD-C annunciator behind the front desk.
Notification Appliances[edit | edit source]
The common areas have Edwards “Genesis” GC-S7VM speaker/strobes (white, ceiling-mount, 70V). The guest rooms have Edwards G4-S7 remote speakers (white, wall-mount, 70V). The pool area has Edwards “Integrity” 757-5A-SS70 speaker/strobes (red, wall-mount, 70V, 15cd).
Initiating Devices[edit | edit source]
Pull Stations[edit | edit source]
All pull stations are Vigilant GSA-M278 addressable dual-action pull stations.
Automatic Detection Devices[edit | edit source]
There are Vigilant V-PS addressable photoelectric smoke detectors throughout the building.