Toggle menu
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.

We have switched hosting. Sorry for the recent downtime. :)

Holy Spirit School (Cochrane)

From FireAlarmPedia
System Specifications
FACP: Notifier NFS-320C
FACP Location: Mechanical Room?
System Type: Single-Stage Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VDC
System Coding: Temporal
Strobes Synchronized: Yes
Date of last known Upgrade: N/A
Year Opened: 2022

Holy Spirit School is an elementary school located at 200 Fireside Drive, in Cochrane, Alberta, Canada. The school is owned by the Calgary Catholic Separate School District, and opened in 2022 to replace the old building after the lease expired. The fire alarm system is original.

System Specifications (2022-present)[edit | edit source]

FACP[edit | edit source]

The school is protected by a Notifier NFS-320C addressable fire alarm system. The panel is likely located in a mechanical room. The system runs Notifier’s FlashScan addressable protocol, and the system coding is temporal.

Annunciators[edit | edit source]

There is a Notifier LCD2-80 annunciator and a Notifier ACM-24AT LED annunciator at the main entrance.

Notification Appliances[edit | edit source]

All of the notification appliances except for one are from System Sensor's "L-Series" line of products.

Most notification appliances are System Sensor P2RLA horn/strobes (red, wall-mount, set to 15cd, bilingual). These are also in each classroom.

The main office and hallways with low ceilings have System Sensor PC2RLA horn/strobes (red, ceiling-mount, set to 30cd bilingual).

The main floor washrooms have System Sensor SCRLA remote strobes (red, ceiling-mount, bilingual, set to 30cd).

The second floor washrooms have System Sensor SRLA remote strobes (red, wall-mount, bilingual, set to 30cd).

For outdoor notification, there is a System Sensor “SpectrAlert Advance” P2RKA weatherproof horn/strobe (red, wall-mount) near the main entrance.

The stairwells have System Sensor B200SWA sounder bases.

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

All pull stations are Notifier NBG-12LX addressable dual-action pull stations. These are located at every exit, and the polling LEDs are green.

Automatic Detection Devices[edit | edit source]

There are Notifier FSP-951A addressable photoelectric smoke detectors throughout the school.

Some areas have Notifier FST-951RA addressable thermal heat detectors.

These are mounted on System Sensor B300A-6 bases in most areas, and on B200SRA sounder bases in the stairwells.

Modules[edit | edit source]

There are Notifier FMM-1A addressable monitor modules supervising the sprinkler system's tamper and flow switches.

There are Notifier FRM-1A addressable relay modules serving various purposes.

There are Notifier ISO-XA isolator modules on the SLC.

EOLs[edit | edit source]

There are Notifier EOL-CR end-of-line resistors on all sprinkler and signal circuits.