Toggle menu
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.

We have switched hosting. Sorry for the recent downtime. :)

23 Sunpark Drive SE, Calgary

From FireAlarmPedia
System Specifications
FACP: Mircom FX-2000
FACP Location: Main Entrance
System Type: Single-Stage Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VFWR
System Coding: Temporal
Strobes Synchronized: No
Date of last known Upgrade: 2016
Year Opened: 2002

23 Sunpark Drive SE is the address of a mixed-use professional building located in the Sundance neighborhood of Southeast Calgary, Alberta, Canada. The building currently houses Pacekids Programs, Service Canada Centre & Passport Services, HealthFirst Optometry, and several other businesses. Most offices currently sit vacant. The building was built in 2002, and the fire alarm system is original with the exception of the horn/strobes in HealthFirst Optometry.

System Specifications[edit | edit source]

FACP[edit | edit source]

The building is protected by a Mircom FX-2000 addressable fire alarm system. The panel is located at the main entrance. The system runs Mircom's CLIP addressable protocol, and the system coding is temporal.

Annunciators[edit | edit source]

There is a Mircom RAX-LCD annunciator in the loading dock hallway, mounted in a Mircom BB-1001 enclosure.

Notification Appliances[edit | edit source]

All areas except HealthFirst Optometry have Mircom "Select-A-Horn/Strobe" FHS-240R horn/strobes (red, wall-mount, 15cd).

HealthFirst Optometry has Mircom FHS-340R horn/strobes (red, wall-mount, set to 15cd). All horn/strobes are likely set to broadband.

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

All pull stations are Mircom MS-401AD addressable single-action pull stations.

Automatic Detection Devices[edit | edit source]

There are Mircom MIX-2251BA addressable photoelectric smoke detectors in some areas, mounted on System Sensor B210LPA bases.

Modules[edit | edit source]

There are Mircom MIX-M500MA addressable monitor modules supervising the sprinkler system's tamper and flow switches.
There are Mircom MIX-M500RA addressable relay modules serving various purposes.

EOLs[edit | edit source]

There are Mircom MP-300 end of line resistor plates on all sprinkler and signal circuits. [[]