System Specifications |
---|
FACP: EST QuickStart QS1
FACP Location: Marshalls Entrance System Coding: Temporal Strobes Synchronized: Yes |
50 4307 130 Avenue SE is the address of a plaza in the South Trail Crossing shopping area of Calgary, Alberta, Canada. The building currently consists of two tenants: Marshalls and HomeSense. The building originally opened in 1999 as a Calgary Co-op grocery store, and was converted to its current state in 2015. The fire alarm system was installed following the 2015 renovation.
System Specifications[edit | edit source]
FACP[edit | edit source]
The building is protected by an EST QuickStart QS1 addressable fire alarm system. The panel is located in the Marshalls main entrance vestibule. The system runs EST's Signature-series addressable protocol, and the system coding is temporal.
Notification Appliances[edit | edit source]
The exterior walls of both stores have EST "Genesis" G1R-HDVM horn/strobes (red, wall-mount, no lettering, set to 15cd).
Areas not near walls have EST GC-HDVM horn/strobes (white, ceiling-mount, no lettering, set to 15cd).
The public washrooms have EST G1R-VM remote strobes (red, wall-mount, no lettering, set to 15cd).
Initiating Devices[edit | edit source]
Pull Stations[edit | edit source]
All pull stations are EST SIGA-270 addressable single-action pull stations.
Automatic Detection Devices[edit | edit source]
None noticed, as all public areas have sprinkler coverage.
Modules[edit | edit source]
There are EST SIGA-CT1 addressable monitor modules supervising the sprinkler system's tamper and flow switches.
Former System Specifications (Co-op)[edit | edit source]
System Specifications |
---|
FACP: Notifier AFP-200
FACP Location: Main Entrance System Coding: Temporal Strobes Synchronized: No |
FACP[edit | edit source]
The store was protected by a Notifier AFP-200 addressable fire alarm system. The panel was located in the main entrance vestibule. The system ran Notifier's CLIP addressable protocol, and the system coding was temporal.
Notification Appliances[edit | edit source]
All notification appliances were System Sensor "SpectrAlert" P2415A horn/strobes (red, wall-mount, 15cd). They were likely set to the electromechanical tone.
Initiating Devices[edit | edit source]
Pull Stations[edit | edit source]
All pull stations were Notifier NFM-950B single-action pull stations. All pull stations were wired to Notifier MMX-101A addressable monitor modules, located directly behind each station.
Automatic Detection Devices[edit | edit source]
None noticed, as all public areas had sprinkler coverage.
Modules[edit | edit source]
There were Notifier MMX-1A addressable monitor modules supervising the sprinkler system's tamper and flow switches.