System Specifications |
---|
FACP: ADT Unimode 10UD System Type: Conventional System Line Voltage: 120VAC NAC Voltage: 24VDC Date of last known Upgrade: 2020 Year Opened: Pre-1914 |
The Barndominium is a small house located just outside Drumheller in Starland County, Alberta. It started its life as a small barn that was built pre-World War I and was converted to a guest house in 2017.
The Fire Alarm System was installed on the 12th of May 2019 by User:AdenK2333, who maintained, tested and conducted fire drills when necessary. File:Barndo1.mp4 On May 26, 2020 the alarm system was decommissioned and removed due to a dispute between the installer and the owner.
On the 31st of May it was announced that a ADT Unimode 10UD shall replace the old panel and all Initiating devices and Notification Appliances will be reused except for one G1-HDVM which was damaged upon temporary installation on another site. User:Yycsfirealarmnimrod now owns the MS-4. This plan came to fruition for approximately 2 days before the permenant system removal requested by the owner.
On July 25, 2020 the alarm system was decommissioned and removed due to a second dispute between the installer and the owner. The system has never been installed in this location since. The panel is now located at [[8327 48 Avenue Garage]]
Former System Specifications[edit | edit source]
FACP[edit | edit source]
The panel was a ADT Unimode 10UD installed as the replacement panel in July 2020. It replaced a Fire-Lite MS-4. It was located by the stairs. It was a used panel, that purchased on eBay previously. System is now defunct, panel is now in use in [[8327 48 Avenue Garag].
Notification Appliances[edit | edit source]
The Barndominium contained three EST Genesis G1-HDVM (white, wall mount, no fire marking) horn/strobes. The owner requested white only without fire marking in order to not distract from the beauty of the establishment as they are small and rather invisible.
Initiating Devices[edit | edit source]
Pull Stations[edit | edit source]
The establishment had 2 Edwards 278B-1120 pull stations for the final days, replacing the hard to reset 270-SPOWB pull stations. The 278B-1120 pull stations are now used in [[8237 48 Ave Garag]
Automatic Detection Devices[edit | edit source]
There were two different automatic detection devices. The downstairs/kitchen detector was a System Sensor C2WTA-BA, 2-wire, photoelectric i3 smoke detector with a thermal sensor and a built-in sounder, the sounder was removed due to it being unneccesary it was configured for alarm verification to avoid false alarms caused by cooking.
The upstairs hallway detector was a System Sensor C2W-BA, 2-wire, photoelectric i3 smoke detector. [[] [[]