| System Specifications |
|---|
| FACP: Edwards iO1000 FACP Location: Main Entrance Vestibule System Type: Single-Stage Addressable System Line Voltage: 120VAC NAC Voltage: 24VFWR System Coding: Temporal Strobes Synchronized: Yes, Genesis Date of last known Upgrade: N/A Most Recent Known Modification: 2021 Year Opened: 2008 |
Graham Construction is a construction company. This page will cover the Calgary office, which is also the headquarters of the company. It is located at 10840 27 St SE, Calgary, Alberta, Canada. The building was completed in 2008, and the fire alarm system is mostly original.
System Specifications
FACP
The building is protected by an Edwards iO1000 addressable fire alarm system. The panel is located in the main entrance vestibule. The system runs Edwards' Signature addressable protocol, and the system coding is temporal.
This panel replaced the original EST QuickStart QS1 in 2021.
Booster Panels
There are three Edwards BPS6A 6-amp booster power supplies on the system, located in the main floor corridor, IT office and pre-action room. The pre-action room serves as the clean agent release.
Notification Appliances
All notification appliances are Edwards "Genesis" G1R-HDVM horn/strobes (red, wall-mount, no marking, set to 15cd).
The suppression release notification appliances are Edwards "Genesis" G1-HDVM horn/strobes (white, wall-mount, no marking, set to 15cd).
Initiating Devices
Pull Stations
All pull stations are EST SIGA-270 addressable single-action pull stations.
Automatic Detection Devices
There are EST SIGA-PS addressable photoelectric smoke detectors located throughout the server room, at the top of each stairwell and at the fire shutters in the basement.
There are EST SIGA-HRS addressable 135°F fixed-temperature/rate-of-rise heat detectors at the top of each elevator shaft.
All detectors are mounted on EST SIGA-SB bases.
There are EST SIGA-SD addressable photoelectric duct smoke detectors on each return air unit.
Modules
There are EST SIGA-CT1 addressable monitor modules supervising the sprinkler system's tamper and flow switches, plus two boosters.
There are EST SIGA-CR addressable relay modules serving various purposes.
There are EST SIGA-CC1 addressable control modules for booster trigger.
There are EST SIGA-IM addressable isolator modules on the SLC.
EOLs
There are Edwards EOL-P1 end-of-line resistor plates on all sprinkler and signal circuits.
Bonus Information
The elevator uses Edwards "Genesis" G1-HD horns (white, no marking, set to continuous) for its alarm.