More actions
System Specifications |
---|
FACP: Notifier NFS-320C FACP Location: Main Entrance Vestibule System Type: Single-Stage Addressable System Line Voltage: 120VAC NAC Voltage: 24VDC System Coding: Temporal Date of last known Upgrade: 2015 Year Opened: 2000 |
Loblaws is a chain of grocery stores across Canada. This particular store is located at 100 McArthur Ave, Ottawa, Ontario, and was built in 2000. The fire alarm system was upgraded circa 2015; the bells are original.
System Specifications (2015-present)[edit | edit source]
FACP[edit | edit source]
The building is protected by a Notifier NFS-320C addressable fire alarm system. The panel is located in the main entrance vestibule. The system runs Notifier’s FlashScan addressable protocol, and the system coding is temporal.
Notification Appliances[edit | edit source]
All notification appliances are Edwards 439D-10AWC vibrating bells (10” gong). These were left over from the previous system.
Initiating Devices[edit | edit source]
Pull Stations[edit | edit source]
All pull stations are Notifier N-MPS-SA addressable single-action pull stations.
Automatic Detection Devices[edit | edit source]
Not currently known. There is a sprinkler system.
Modules[edit | edit source]
There are Notifier FMM-1A addressable monitor modules supervising the sprinkler system's tamper and flow switches.
EOLs[edit | edit source]
There are Edwards EOL-P1 end of line resistor plates on all sprinkler and signal circuits.
System Specifications (2000-2015)[edit | edit source]
System Specifications |
---|
FACP: Edwards EST2 FACP Location: Main Entrance Vestibule System Type: Single-Stage Addressable System Line Voltage: 120VAC NAC Voltage: 24VDC System Coding: Continuous Year Installed: 2000 Year Decommissioned: 2015 |
FACP[edit | edit source]
The building was protected by an Edwards EST2 addressable fire alarm system. The panel was located in the main entrance vestibule. The system ran EST’s Signature addressable protocol, and the system coding was likely continuous
Notification Appliances[edit | edit source]
All notification appliances were Edwards 439D-10AWC vibrating bells (10” gong). These are still in use on the Notifier system.
Initiating Devices[edit | edit source]
Pull Stations[edit | edit source]
All pull stations were EST SIGC-270B addressable single-action pull stations.
Automatic Detection Devices[edit | edit source]
Not known. There was a sprinkler system.
Modules[edit | edit source]
There were EST SIGA-CT1 addressable monitor modules supervising the sprinkler system's tamper and flow switches.
EOLs[edit | edit source]
There were Edwards EOL-P1 end of line resistor plates on all sprinkler and signal circuits.