| System Specifications |
|---|
| FACP: Mircom FA-1000 FACP Location: Main Entrance System Type: Single-Stage Conventional System Line Voltage: 120VAC NAC Voltage: 24VFWR System Coding: Temporal Strobes Synchronized: No Date of last known Upgrade: N/A Most Recent Known Modification: N/A Year Opened: 2004 |
Soho Suites is an apartment building located at 323 18 Ave SW, in Calgary, Alberta, Canada. The building was built in 2004, and the fire alarm system is original.
System Specifications
Please note that these details are accurate to 2020.
FACP
The building is protected by a Mircom FA-1000 conventional fire alarm system. The panel is located at the main entrance. The system coding is temporal.
Notification Appliances
All common area notification appliances are Mircom "Select-A-Horn/Strobe" FHS-240R horn/strobes (red, wall-mount, set to 15cd).
All suites have Mircom MH-S25WA silenceable mini-horns (white) paired with Mircom "Select-A-Strobe" FS-240R remote strobes (red, wall-mount, set to 15cd).
Initiating Devices
Pull Stations
All pull stations are Mircom MS-401 conventional single-action pull stations.
Automatic Detection Devices
There are System Sensor C2W-BA conventional photoelectric smoke detectors throughout all corridors and at the top of each stairwell.
EOLs
There are Mircom MP-300 end of line resistor plates on all circuits.