Toggle search
Search
Toggle menu
129
57
47
11K
FireAlarmPedia
Navigation
Main page
Recent changes
Random page
All Pages
Facility Page Template
Contact Us
Special pages
Upload file
notifications
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.
user-interface-preferences
Personal tools
Talk
Contributions
Log in
We have switched hosting. Sorry for the recent downtime. :)
Editing
Bow Crow Forestry Services
(Satellite Office)
From FireAlarmPedia
Views
Read
Edit
Edit source
View history
associated-pages
Page
Discussion
More actions
Warning:
You are not logged in. Your IP address will be publicly visible if you make any edits. If you
log in
or
create an account
, your edits will be attributed to your username, along with other benefits.
Anti-spam check. Do
not
fill this in!
{| style="float:right;border:2px solid black" |- ! System Specifications |- | |- | FACP: EST FireShield FS302G <br />FACP Location: Main Entrance Vestibule <br />System Type: Single-Stage Conventional <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: Continuous <br />Date of last known Upgrade: 2000s <br />Year Opened: 1968 |} '''Bow Crow Forestry Services''' is a wildfire and forest service located at 8660 Bearspaw Dam Road NW, Calgary, AB. This page will cover the satellite office. The building was built in 1968, and the fire alarm system was upgraded in the late 1990s. == System Specifications (late 1990s-present) == ==== FACP ==== The building is protected by an EST FireShield FS302G conventional fire alarm system. The panel is located in the main entrance vestibule. The system coding is continuous. ==== Notification Appliances ==== The only notification appliance is an Edwards 439D-10AWC vibrating bell (10β gong). === Initiating Devices === ==== Pull Stations ==== All pull stations are Edwards 270-SPO conventional single-action pull stations. ==== Automatic Detection Devices ==== There are System Sensor βi3β C2W-BA conventional photoelectric smoke detectors throughout the building. <br> Some areas have Edwards 281C conventional 135ΰ₯°F fixed-temperature/rate-of-rise heat detectors. ==== EOLs ==== There are Edwards EOL-P1 end-of-line resistor plates on all circuits. [[Category:Calgary]] [[Category:Government Services]]
Summary:
Please note that all contributions to FireAlarmPedia may be edited, altered, or removed by other contributors. If you do not want your writing to be edited mercilessly, then do not submit it here.
You are also promising us that you wrote this yourself, or copied it from a public domain or similar free resource (see
FireAlarmPedia:Copyrights
for details).
Do not submit copyrighted work without permission!
Cancel
Editing help
(opens in new window)