Toggle menu
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.

We have switched hosting. Sorry for the recent downtime. :)

Jasper Station: Difference between revisions

From FireAlarmPedia
No edit summary
(EOL up ass)
 
Line 5: Line 5:
|
|
|-
|-
|FACP: Notifier NFS-320C <br />FACP Location: Unknown <br />System Type: Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br />System Coding: Temporal <br>Strobes Synchronized: Yes, SS <br />Date of last known Upgrade: 2010s <br />Year Opened: 1926
|FACP: Notifier NFS-320C <br />FACP Location: Unknown <br />System Type: Single-Stage Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VDC <br />System Coding: Temporal <br>Strobes Synchronized: Yes, System Sensor <br />Date of last known Upgrade: 2010s <br />Year Opened: 1926
|}
|}
'''Jasper Station''' is a heritage train station located at 607 Connaught Drive, Jasper, AB. It serves as a station on VIA Rail and Rocky Mountaineer railway lines. It was built in 1926, and the fire alarm system was upgraded in the 2000s.  
'''Jasper Station''' is a heritage train station located at 607 Connaught Drive, Jasper, AB. It serves as a station on VIA Rail and Rocky Mountaineer railway lines. It was built in 1926, and the fire alarm system was upgraded in the 2000s.  
Line 17: Line 17:
===Initiating Devices===
===Initiating Devices===
====Pull Stations====
====Pull Stations====
The pull stations are a mix of Notifier MPS-950B conventional pull stations and NFM-950B conventional pull stations; most are NFM-950B. All pull stations are wired to Notifier FMM-101A addressable modules, located directly behind each station.
The pull stations are a mix of Notifier MPS-950B conventional pull stations and NFM-950B conventional pull stations; most are NFM-950B. All pull stations are wired to Notifier FMM-101A addressable monitor modules.
====Automatic Detection Devices====
====Automatic Detection Devices====
None noticed. There is a sprinkler system with waterflow detection.
None noticed.
====Modules====
====Modules====
There are Notifier FMM-1A addressable monitor modules supervising the sprinkler system’s tamper and flow switches.
There are Notifier FMM-1A addressable monitor modules supervising the sprinkler system’s tamper and flow switches.
==== EOLs ====
There are Notifier EOL-CR end of line resistor plates on all sprinkler and signal circuits.
[[Category:Alberta]]
[[Category:Alberta]]
[[Category:Train Stations]]
[[Category:Train Stations]]

Latest revision as of 11:50, 30 September 2024

System Specifications
FACP: Notifier NFS-320C
FACP Location: Unknown
System Type: Single-Stage Addressable
System Line Voltage: 120VAC
NAC Voltage: 24VDC
System Coding: Temporal
Strobes Synchronized: Yes, System Sensor
Date of last known Upgrade: 2010s
Year Opened: 1926

Jasper Station is a heritage train station located at 607 Connaught Drive, Jasper, AB. It serves as a station on VIA Rail and Rocky Mountaineer railway lines. It was built in 1926, and the fire alarm system was upgraded in the 2000s.

System Specifications (2000s-present)[edit | edit source]

FACP[edit | edit source]

The station is protected by a Notifier NFS-320C addressable fire alarm system. The panel location is unknown. It replaced a Notifier AFP-200C in the 2010s. The system runs Notifier’s FlashScan addressable protocol, and the system coding is temporal.

Annunciators[edit | edit source]

There is a Notifier LCD2-80 LCD annunciator paired with an ACM-24AT LED annunciator at the entrance.

Notification Appliances[edit | edit source]

All notification appliances are System Sensor “SpectrAlert” P2415A horn/strobes (red, wall-mount, set to electromechanical, 15cd).

Initiating Devices[edit | edit source]

Pull Stations[edit | edit source]

The pull stations are a mix of Notifier MPS-950B conventional pull stations and NFM-950B conventional pull stations; most are NFM-950B. All pull stations are wired to Notifier FMM-101A addressable monitor modules.

Automatic Detection Devices[edit | edit source]

None noticed.

Modules[edit | edit source]

There are Notifier FMM-1A addressable monitor modules supervising the sprinkler system’s tamper and flow switches.

EOLs[edit | edit source]

There are Notifier EOL-CR end of line resistor plates on all sprinkler and signal circuits.