| FACP: Kidde VS4 <br /> FACP Location: Parkade Fire Alarm Room <br />System Type: Hybrid <br /> System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br /> System Coding: Temporal <br> Strobes Synchronized: Yes, Genesis <br />Date of last known Upgrade: 2021 <br />Year Opened: 1974 | | FACP: Kidde VS4 <br />FACP Location: Parkade Fire Alarm Room <br />System Type: Single-Stage Hybrid-Addressable <br />System Line Voltage: 120VAC<br />NAC Voltage: 24VFWR <br />System Coding: Temporal <br>Strobes Synchronized: Yes, Genesis <br />Date of last known Upgrade: 2021 <br />Year Opened: 1974 | ||
|} | |} | ||
'''Mission Centre''' is an office tower located at 2303 4 St SW, in Calgary, Alberta, Canada. The building opened in 1974, and the fire alarm system was upgraded in 2021. | |||
'''Mission Centre''' is an office tower located at 2303 4 | |||
==System Specifications (2021-present)== | ==System Specifications (2021-present)== | ||
====FACP==== | ====FACP==== | ||
The building is protected by a Kidde VS4 hybrid-addressable fire alarm system. | The building is protected by a Kidde VS4 hybrid-addressable fire alarm system. The panel is located in the parkade fire alarm room. The system runs Kidde’s GSA addressable protocol, and the system coding is temporal. | ||
=====Annunciators===== | =====Annunciators===== | ||
There is a Kidde K-RLCD-C annunciator paired with a Kidde K-RLED24 annunciator behind the security desk. | There is a Kidde K-RLCD-C annunciator paired with a Kidde K-RLED24 annunciator behind the security desk. Both annunciators are mounted in a Kidde RA-ENC2 annunciator enclosure. | ||
====Notification Appliances==== | ====Notification Appliances==== | ||
All notification appliances are Edwards “Genesis” G1AVRF horn/strobes (red, wall-mount, set to 15cd). | All notification appliances are Edwards “Genesis” G1AVRF horn/strobes (red, wall-mount, set to 15cd). | ||
===Initiating Devices=== | ===Initiating Devices=== | ||
====Pull Stations==== | ====Pull Stations==== | ||
Most pull stations are Vigilant GSA-M270 addressable single-action pull stations. | Most pull stations are Vigilant GSA-M270 addressable single-action pull stations. Some areas have Mircom MS-401 conventional single-action pull stations, remaining from the previous system. | ||
====Automatic Detection Devices==== | |||
There are Kidde KI-PD addressable photoelectric smoke detectors throughout the building, mounted on Kidde KI-SB bases. The parkade has FDD CF-135 conventional 135°F fixed-temperature heat detectors. | |||
==== | ==== EOLs ==== | ||
There are | There are Edwards EOL-P1 end of line resistor plates on all signal circuits. | ||
[[Category:Calgary]] | |||
[[Category:Commercial]] |
Latest revision as of 14:16, 13 October 2024
System Specifications |
---|
FACP: Kidde VS4 FACP Location: Parkade Fire Alarm Room System Type: Single-Stage Hybrid-Addressable System Line Voltage: 120VAC NAC Voltage: 24VFWR System Coding: Temporal Strobes Synchronized: Yes, Genesis Date of last known Upgrade: 2021 Year Opened: 1974 |
Mission Centre is an office tower located at 2303 4 St SW, in Calgary, Alberta, Canada. The building opened in 1974, and the fire alarm system was upgraded in 2021.
System Specifications (2021-present)[edit | edit source]
FACP[edit | edit source]
The building is protected by a Kidde VS4 hybrid-addressable fire alarm system. The panel is located in the parkade fire alarm room. The system runs Kidde’s GSA addressable protocol, and the system coding is temporal.
Annunciators[edit | edit source]
There is a Kidde K-RLCD-C annunciator paired with a Kidde K-RLED24 annunciator behind the security desk. Both annunciators are mounted in a Kidde RA-ENC2 annunciator enclosure.
Notification Appliances[edit | edit source]
All notification appliances are Edwards “Genesis” G1AVRF horn/strobes (red, wall-mount, set to 15cd).
Initiating Devices[edit | edit source]
Pull Stations[edit | edit source]
Most pull stations are Vigilant GSA-M270 addressable single-action pull stations. Some areas have Mircom MS-401 conventional single-action pull stations, remaining from the previous system.
Automatic Detection Devices[edit | edit source]
There are Kidde KI-PD addressable photoelectric smoke detectors throughout the building, mounted on Kidde KI-SB bases. The parkade has FDD CF-135 conventional 135°F fixed-temperature heat detectors.
EOLs[edit | edit source]
There are Edwards EOL-P1 end of line resistor plates on all signal circuits.